Show simple item record

Standard Practice for Capping Cylindrical Concrete Specimens

contributor authorAASHTO - American Association of State Highway and Transportation Officials
date accessioned2017-09-04T15:41:38Z
date available2017-09-04T15:41:38Z
date copyright01/01/2013
date issued2013
identifier otherPHFBGFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/43905
description abstractThis method covers apparatus, materials, and procedures for capping freshly molded concrete cylinders with neat cement and hardened cylinders and drilled concrete cores with high-strength gypsum plaster or sulfur mortar.
The values stated in SI units are the preferred standard.
This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precaution statements.
languageEnglish
titleAASHTO T 231num
titleStandard Practice for Capping Cylindrical Concrete Specimensen
typestandard
page9
statusActive
treeAASHTO - American Association of State Highway and Transportation Officials:;2013
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record