MIL-DTL-24308G (2)

CONNECTORS, ELECTRIC, RECTANGULAR, NONENVIRONMENTAL, MINIATURE, POLARIZED SHELL, RACK AND PANEL, GENERAL SPECIFICATION FOR

Organization:
DLA - CC - DLA Land and Maritime
Year: 2012

Abstract: This specification covers the requirements for nonenvironmental, polarized shell, miniature, rack and panel connectors having pin and socket, crimp (removable), solder (nonremovable), or insulation displacement (nonremovable) contacts with rigid or float mounting, designed for -55°C to +125°C operating temperature range.Intended Use: These connectors are intended for general military use. Connector installations should be designed to assure that connectors are mated within the limits specified in 3.4.5. The class and types of connectors are intended for application as follows: a. Classes G and N connectors are intended for use in applications where the operating temperature range -55° to +125°C is experienced. Crimp contact connectors have the additional advantage of possessing removable crimp-type contacts. b. Class N connectors are intended for use in applications where the presence of residual magnetism must be held to very low levels to avoid interference with nearby sensitive instrumentation. c. Class H receptacles are intended for use in applications where atmospheric pressures must be contained by the connectors across the wall or panels on which they are mounted. If air leakage requirements are critical, a class H connector should be used. d. Crimp contact connectors should have contacts present in all positions when the connector is installed. e. Classes D, K, and M connectors are for high reliability space applications. f. Connector installations should be designed to assure that connectors are mated within the limits specified in 3.4.5.
URI: https://yse.yabesh.ir/std/handle/yse/46266
Collections :
  • DLA - CC - DLA Land and Maritime
  • Download PDF : (528.3Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    MIL-DTL-24308G (2)

Show full item record

contributor authorDLA - CC - DLA Land and Maritime
date accessioned2017-09-04T15:43:55Z
date available2017-09-04T15:43:55Z
date copyright08/01/2012
date issued2012
identifier otherPNPXXEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/46266
description abstractThis specification covers the requirements for nonenvironmental, polarized shell, miniature, rack and panel connectors having pin and socket, crimp (removable), solder (nonremovable), or insulation displacement (nonremovable) contacts with rigid or float mounting, designed for -55°C to +125°C operating temperature range.Intended Use: These connectors are intended for general military use. Connector installations should be designed to assure that connectors are mated within the limits specified in 3.4.5. The class and types of connectors are intended for application as follows: a. Classes G and N connectors are intended for use in applications where the operating temperature range -55° to +125°C is experienced. Crimp contact connectors have the additional advantage of possessing removable crimp-type contacts. b. Class N connectors are intended for use in applications where the presence of residual magnetism must be held to very low levels to avoid interference with nearby sensitive instrumentation. c. Class H receptacles are intended for use in applications where atmospheric pressures must be contained by the connectors across the wall or panels on which they are mounted. If air leakage requirements are critical, a class H connector should be used. d. Crimp contact connectors should have contacts present in all positions when the connector is installed. e. Classes D, K, and M connectors are for high reliability space applications. f. Connector installations should be designed to assure that connectors are mated within the limits specified in 3.4.5.
languageEnglish
titleMIL-DTL-24308G (2)num
titleCONNECTORS, ELECTRIC, RECTANGULAR, NONENVIRONMENTAL, MINIATURE, POLARIZED SHELL, RACK AND PANEL, GENERAL SPECIFICATION FORen
typestandard
page41
statusActive
treeDLA - CC - DLA Land and Maritime:;2012
contenttypefulltext