Show simple item record

CLAMP, LOOP, TUBE-17-7 PH CRES, 500 DEGREES F

contributor authorNAVY - AS - Naval Air Systems Command
date accessioned2017-09-04T15:45:45Z
date available2017-09-04T15:45:45Z
date copyright03/30/2005
date issued2005
identifier otherPTBSHBAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/48317
description abstractIntended Use: These clamps are intended for use as follows: Temperature range: - 65 to + 500 °F. These clamps have cushions, which have been compounded for high temperature capability at the sacrifice of fluid resistance. It is recommended for use only in those areas with operating temperatures from 275 °F to 500 °F where fluid exposure is minimal. For application below 275 °F, the use of clamps with a higher degree of fluid resistance is recommended such as MIL-DTL-85052/1 or MIL-DTL-85052/2 clamps. Systems: All fluid and electrical systems application in high temperature areas. Vibration rating: Clamps are used at low, medium, and high vibration areas depending on mounting methods. The recommended mounting methods for various vibration areas are specified in 6.4 of the general specification. Change from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes.
languageEnglish
titleMIL-DTL-85052/3Cnum
titleCLAMP, LOOP, TUBE-17-7 PH CRES, 500 DEGREES Fen
typestandard
page6
statusActive
treeNAVY - AS - Naval Air Systems Command:;2005
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record