NASA-LLIS-0541
Lessons Learned - Vacuum System Load and Ion Pump Selection
Year: 1996
Abstract: Description of Driving Event:
On MIDAS, an ion pump was purchased to be the maintaining pump on a chamber before all vapor and leak loads within the chamber were calculated (or measured). This resulted in the ion pump being at its maximum pumping capacity during normal operation.
On MIDAS, an ion pump was purchased to be the maintaining pump on a chamber before all vapor and leak loads within the chamber were calculated (or measured). This resulted in the ion pump being at its maximum pumping capacity during normal operation.
Subject: Hardware
Show full item record
| contributor author | NASA - National Aeronautics and Space Administration (NASA) | |
| date accessioned | 2017-09-04T15:46:42Z | |
| date available | 2017-09-04T15:46:42Z | |
| date copyright | 02/01/1996 | |
| date issued | 1996 | |
| identifier other | PWBEQCAAAAAAAAAA.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/49419 | |
| description abstract | Description of Driving Event: On MIDAS, an ion pump was purchased to be the maintaining pump on a chamber before all vapor and leak loads within the chamber were calculated (or measured). This resulted in the ion pump being at its maximum pumping capacity during normal operation. | |
| language | English | |
| title | NASA-LLIS-0541 | num |
| title | Lessons Learned - Vacuum System Load and Ion Pump Selection | en |
| type | standard | |
| page | 2 | |
| status | Active | |
| tree | NASA - National Aeronautics and Space Administration (NASA):;1996 | |
| contenttype | fulltext | |
| subject keywords | Hardware | |
| subject keywords | Pressure Vessels |