MIL-DTL-25038J

WIRE, ELECTRICAL, HIGH TEMPERATURE, FIRE RESISTANT, AND FLIGHT CRITICAL

Organization:
DLA - CC - DLA Land and Maritime
Year: 2012

Abstract: This specification covers insulated single wire for electrical use in flight critical circuits and under short-time emergency conditions involving exposure to flames with temperatures up to 2,000 °FIntended Use: The basic insulated wire covered by this specification is intended for use in circuits in high performance military aircraft where it is necessary to maintain the electrical integrity of the insulated conductor for 15 minutes in a 2,000 °F flame, with the operating potentials not exceeding 125 V rms.
URI: https://yse.yabesh.ir/std/handle/yse/70744
Subject: Endurance
Collections :
  • DLA - CC - DLA Land and Maritime
  • Download PDF : (275.8Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    MIL-DTL-25038J

Show full item record

contributor authorDLA - CC - DLA Land and Maritime
date accessioned2017-09-04T16:07:34Z
date available2017-09-04T16:07:34Z
date copyright01/10/2012
date issued2012
identifier otherSBOVTEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/70744
description abstractThis specification covers insulated single wire for electrical use in flight critical circuits and under short-time emergency conditions involving exposure to flames with temperatures up to 2,000 °FIntended Use: The basic insulated wire covered by this specification is intended for use in circuits in high performance military aircraft where it is necessary to maintain the electrical integrity of the insulated conductor for 15 minutes in a 2,000 °F flame, with the operating potentials not exceeding 125 V rms.
languageEnglish
titleMIL-DTL-25038Jnum
titleWIRE, ELECTRICAL, HIGH TEMPERATURE, FIRE RESISTANT, AND FLIGHT CRITICALen
typestandard
page21
statusActive
treeDLA - CC - DLA Land and Maritime:;2012
contenttypefulltext
subject keywordsEndurance
subject keywordsFlame
subject keywordsPolytetrafluoroethylene (PTFE)
subject keywordsTensile strength
subject keywordsWet dielectric
subject keywordsWicking