Archive

NASA-LLIS-0053

Lessons Learned - Keyed Connector Mismating; Mating of Electrical Connectors in Areas of Limited Visibility; Kapton Wire Insulation Breakdown

Organization:
NASA - National Aeronautics and Space Administration (NASA)
Year: 1992

Abstract: Description of Driving Event:
The primary cause of the Magellan mishap was the inadvertent mating of at least two pins of the spacecraft harness connector P2 to connector J3 of battery 1. The mismate of these connectors created an electrical short circuit within the J3 connector that resulted in electrical arcs and additional short circuits that, using the energy stored in the battery, produced damage to battery 1, connector P2, and the battery thermal blanket.
URI: https://yse.yabesh.ir/std/handle/yse/72372
Subject: Energy
Collections :
  • NASA - National Aeronautics and Space Administration (NASA)
  • Download PDF : (13.21Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NASA-LLIS-0053

Show full item record

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T16:09:08Z
date available2017-09-04T16:09:08Z
date copyright01/10/1992
date issued1992
identifier otherSFYCQCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/72372
description abstractDescription of Driving Event:
The primary cause of the Magellan mishap was the inadvertent mating of at least two pins of the spacecraft harness connector P2 to connector J3 of battery 1. The mismate of these connectors created an electrical short circuit within the J3 connector that resulted in electrical arcs and additional short circuits that, using the energy stored in the battery, produced damage to battery 1, connector P2, and the battery thermal blanket.
languageEnglish
titleNASA-LLIS-0053num
titleLessons Learned - Keyed Connector Mismating; Mating of Electrical Connectors in Areas of Limited Visibility; Kapton Wire Insulation Breakdownen
typestandard
page2
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1992
contenttypefulltext
subject keywordsEnergy
subject keywordsGround Operations
subject keywordsHardware
subject keywordsPackaging Handling Storage
subject keywordsSpacecraft
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian