NASA-LLIS-0444

Lessons Learned - Electrical Connectors

Organization:
NASA - National Aeronautics and Space Administration (NASA)
Year: 1993

Abstract: Description of Driving Event:
During mating of the Magellan Spacecraft connectors within the forward equipment module (a confined space with limited visibility), the technician observed sparks, flames, and smoke. The primary cause was the inadvertent mating of at least two pins of the spacecraft harness connector P2 to connector J3 of Battery 1. The mismate of these connectors created an electrical short circuit within the J3 connector that, using the energy stored in the battery, produced the damage on Battery 1, connector P2 and the battery thermal blanket.
URI: https://yse.yabesh.ir/std/handle/yse/75014
Subject: Energy
Collections :
  • NASA - National Aeronautics and Space Administration (NASA)
  • Download PDF : (12.83Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NASA-LLIS-0444

Show full item record

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T16:11:50Z
date available2017-09-04T16:11:50Z
date copyright07/30/1993
date issued1993
identifier otherSNBEQCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/75014
description abstractDescription of Driving Event:
During mating of the Magellan Spacecraft connectors within the forward equipment module (a confined space with limited visibility), the technician observed sparks, flames, and smoke. The primary cause was the inadvertent mating of at least two pins of the spacecraft harness connector P2 to connector J3 of Battery 1. The mismate of these connectors created an electrical short circuit within the J3 connector that, using the energy stored in the battery, produced the damage on Battery 1, connector P2 and the battery thermal blanket.
languageEnglish
titleNASA-LLIS-0444num
titleLessons Learned - Electrical Connectorsen
typestandard
page2
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1993
contenttypefulltext
subject keywordsEnergy
subject keywordsHardware
subject keywordsParts Materials & Processes