DESC-DWG-91026

CONNECTORS, ELECTRICAL, RECTANGULAR, POLARIZED SHELL, HIGH DENSITY, NANOMINIATURE, GENERAL REQUIREMENTS FOR

Organization:
DLA - CC - DLA Land and Maritime
Year: 1993

Abstract: This drawing outlines the general requirements for families of high density, high performance electrical connectors, intended for general usage where space and weight are of primary concern. These connectors utilize attached harness, printed circuit through hole or printed circuit surface mount termination means, and include features for polarization or keying. Interface contact patterns for these connectors is on a 6.35 millimeter (0.025 inch) spacing grid.
Connectors conforming to this general requirements drawing must be capable of operating in the following environments:
a. Temperature from −65°C to +125°C with temperature cycling.
b. Altitudes from sea level to 21,336 meters (70,000 ft).
c. Moisture conditions up to 100{}elative humidity.
d. Dust and fine sand atmosphere.
e. Salt laden atmosphere.
f. Vibration conditions to 20 g's.
g. Shock conditions up to 100 g's.
The complete PIN shall be as specified on the individual requirements drawing and constructed using the following format, (also see 1.2.6): CHART
Insulators shall be fabricated utilizing one of the following plastic materials:
a. Thermoplastic, type GST-40F per MIL-M-24519.
b. Thermosetting plastic, type GDI-390F per MIL-M-14.
c. Thermoplastic, type GLCP-30F per MIL-M-24519.
Connectors shall be terminated using the following techniques:
a. Attached solid uninsulated wire harness.
b. Attached stranded insulated wire harness.
c. Printed circuit vertical through hole mount.
d. Printed circuit right angle through hole mount.
e. Printed circuit vertical surface mount.
f. Printed circuit right angle surface mount.
g. Ribbon cable.
h. Flex circuitry.
The PIN shall include 5 digits to identify the total number of contacts. The first three digits will identify the number of signal contacts and the following two digits identifying the number of special contacts (shielded, power, etc...). CHART
The PIN will utilize a single character (A to Z) to identify the termination type. Each individual requirement drawing will provide a chart which will identify available termination type and an associated code letter to be included in the PIN.
Contact sealing will be identified in the last character position of the PIN as follows:
     S  -  Connectors are sealed to prevent entry of cleaning fluids, or conformal coatings            into the contact area from the termination side of the connector.       N  -  No sealing is provided.


Mounting and keying hardware will be specified in the last character position of the PIN. Each individual requirements drawing will provide a chart which will identify available mounting and keying hardware options and an associated code letter (A to Z) to be included in the PIN.
Ancillary hardware, when specified on an individual requirements drawing, shall be specified in the following format: CHART
Intended Use: These connectors are designed for printed wiring board to printed wiring board, printed wiring board to cable, cable to panel, or cable to cable interconnections of miniaturized equipment sub-assemblies with low power requirements.
URI: https://yse.yabesh.ir/std/handle/yse/75216
Collections :
  • DLA - CC - DLA Land and Maritime
  • Download PDF : (992.2Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    DESC-DWG-91026

Show full item record

contributor authorDLA - CC - DLA Land and Maritime
date accessioned2017-09-04T16:12:00Z
date available2017-09-04T16:12:00Z
date copyright07/07/1993
date issued1993
identifier otherSNPYDAAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/75216
description abstractThis drawing outlines the general requirements for families of high density, high performance electrical connectors, intended for general usage where space and weight are of primary concern. These connectors utilize attached harness, printed circuit through hole or printed circuit surface mount termination means, and include features for polarization or keying. Interface contact patterns for these connectors is on a 6.35 millimeter (0.025 inch) spacing grid.
Connectors conforming to this general requirements drawing must be capable of operating in the following environments:
a. Temperature from −65°C to +125°C with temperature cycling.
b. Altitudes from sea level to 21,336 meters (70,000 ft).
c. Moisture conditions up to 100{}elative humidity.
d. Dust and fine sand atmosphere.
e. Salt laden atmosphere.
f. Vibration conditions to 20 g's.
g. Shock conditions up to 100 g's.
The complete PIN shall be as specified on the individual requirements drawing and constructed using the following format, (also see 1.2.6): CHART
Insulators shall be fabricated utilizing one of the following plastic materials:
a. Thermoplastic, type GST-40F per MIL-M-24519.
b. Thermosetting plastic, type GDI-390F per MIL-M-14.
c. Thermoplastic, type GLCP-30F per MIL-M-24519.
Connectors shall be terminated using the following techniques:
a. Attached solid uninsulated wire harness.
b. Attached stranded insulated wire harness.
c. Printed circuit vertical through hole mount.
d. Printed circuit right angle through hole mount.
e. Printed circuit vertical surface mount.
f. Printed circuit right angle surface mount.
g. Ribbon cable.
h. Flex circuitry.
The PIN shall include 5 digits to identify the total number of contacts. The first three digits will identify the number of signal contacts and the following two digits identifying the number of special contacts (shielded, power, etc...). CHART
The PIN will utilize a single character (A to Z) to identify the termination type. Each individual requirement drawing will provide a chart which will identify available termination type and an associated code letter to be included in the PIN.
Contact sealing will be identified in the last character position of the PIN as follows:
     S  -  Connectors are sealed to prevent entry of cleaning fluids, or conformal coatings            into the contact area from the termination side of the connector.       N  -  No sealing is provided.


Mounting and keying hardware will be specified in the last character position of the PIN. Each individual requirements drawing will provide a chart which will identify available mounting and keying hardware options and an associated code letter (A to Z) to be included in the PIN.
Ancillary hardware, when specified on an individual requirements drawing, shall be specified in the following format: CHART
Intended Use: These connectors are designed for printed wiring board to printed wiring board, printed wiring board to cable, cable to panel, or cable to cable interconnections of miniaturized equipment sub-assemblies with low power requirements.
languageEnglish
titleDESC-DWG-91026num
titleCONNECTORS, ELECTRICAL, RECTANGULAR, POLARIZED SHELL, HIGH DENSITY, NANOMINIATURE, GENERAL REQUIREMENTS FORen
typestandard
page15
statusActive
treeDLA - CC - DLA Land and Maritime:;1993
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian