MIL-I-3158D
INSULATION TAPE, ELECTRICAL GLASS-FIBER (RESIN-FILLED): AND CORD, FIBROUS-GLASS
Organization:
NAVY - SH - Naval Sea Systems Command (Ship Systems)
Year: 1968
Abstract: This specification covers resin treated glass-fiber electrical insulation for use in the insulation of electric cables.
Electrical insulation shall be of the following forms and types, as specified (see 6.2):
Intended Use: Type SR-1 material is intended for general use in the installation of electric cables, but particularly for cable sealing in accordance with NAVSEC drawing 9000-S6200-73980. Types, SR-4 and SR-5 material are intended for use in serving insulating materials used in the installation of electric cables. Type SR-4.5 material is intended for use as lacing cord in the installation of electrical cables in applications such as switchboards.
Electrical insulation shall be of the following forms and types, as specified (see 6.2):
Tape: Type SR-1 - Coated, Frayproof (for cable sealing). Cordage: Type SR-4 - For cable installation. Type SR-4.5 - Lacing cord for cable installation. Type SR-5 - For cable installation (color coded).
Intended Use: Type SR-1 material is intended for general use in the installation of electric cables, but particularly for cable sealing in accordance with NAVSEC drawing 9000-S6200-73980. Types, SR-4 and SR-5 material are intended for use in serving insulating materials used in the installation of electric cables. Type SR-4.5 material is intended for use as lacing cord in the installation of electrical cables in applications such as switchboards.
Collections
:
Show full item record
| contributor author | NAVY - SH - Naval Sea Systems Command (Ship Systems) | |
| date accessioned | 2017-09-04T15:09:30Z | |
| date available | 2017-09-04T15:09:30Z | |
| date copyright | 25118 | |
| date issued | 1968 | |
| identifier other | LOFIDAAAAAAAAAAA.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/7582 | |
| description abstract | This specification covers resin treated glass-fiber electrical insulation for use in the insulation of electric cables. Electrical insulation shall be of the following forms and types, as specified (see 6.2): Tape: Type SR-1 - Coated, Frayproof (for cable sealing). Cordage: Type SR-4 - For cable installation. Type SR-4.5 - Lacing cord for cable installation. Type SR-5 - For cable installation (color coded). Intended Use: Type SR-1 material is intended for general use in the installation of electric cables, but particularly for cable sealing in accordance with NAVSEC drawing 9000-S6200-73980. Types, SR-4 and SR-5 material are intended for use in serving insulating materials used in the installation of electric cables. Type SR-4.5 material is intended for use as lacing cord in the installation of electrical cables in applications such as switchboards. | |
| language | English | |
| title | MIL-I-3158D | num |
| title | INSULATION TAPE, ELECTRICAL GLASS-FIBER (RESIN-FILLED): AND CORD, FIBROUS-GLASS | en |
| type | standard | |
| page | 9 | |
| status | Active | |
| tree | NAVY - SH - Naval Sea Systems Command (Ship Systems):;1968 | |
| contenttype | fulltext |