Abstract: Description of Driving Event:
Clean room certified adhesive tape 5413 was used inadvertently in construction of multi-layer insulation (MLI) blanket for a vacuum chamber (instead of clean room certified adhesive tape 1205). The two tapes look virtually identical and are packaged similarly.
Clean room certified adhesive tape 5413 was used inadvertently in construction of multi-layer insulation (MLI) blanket for a vacuum chamber (instead of clean room certified adhesive tape 1205). The two tapes look virtually identical and are packaged similarly.
Subject: Parts Materials & Processes
Show full item record
| contributor author | NASA - National Aeronautics and Space Administration (NASA) | |
| date accessioned | 2017-09-04T16:13:57Z | |
| date available | 2017-09-04T16:13:57Z | |
| date copyright | 05/01/1996 | |
| date issued | 1996 | |
| identifier other | STBEQCAAAAAAAAAA.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/77260 | |
| description abstract | Description of Driving Event: Clean room certified adhesive tape 5413 was used inadvertently in construction of multi-layer insulation (MLI) blanket for a vacuum chamber (instead of clean room certified adhesive tape 1205). The two tapes look virtually identical and are packaged similarly. | |
| language | English | |
| title | NASA-LLIS-0536 | num |
| title | Lessons Learned - Clean Room Certified Adhesive Tapes: Silicone vs. Acrylic | en |
| type | standard | |
| page | 2 | |
| status | Active | |
| tree | NASA - National Aeronautics and Space Administration (NASA):;1996 | |
| contenttype | fulltext | |
| subject keywords | Parts Materials & Processes |

درباره ما