IEEE 43

Recommended Practice for Testing Insulation Resistance of Rotating Machinery

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2006

Abstract: This document describes a recommended procedure for measuring insulation resistance of armature and field windings in rotating machines rated 1 hp, 750 W or greater. It applies to synchronous machines, induction machines, dc machines, and synchronous condensers. It does not apply to fractional-horsepower machines.
The document also describes typical insulation resistance characteristics of rotating machine windings and how these characteristics indicate winding condition. It recommends minimum acceptable values of insulation resistance for ac and dc rotating machine windings.
Other IEEE standards that include information on insulation resistance measurement are listed in Clause 2.
URI: https://yse.yabesh.ir/std/handle/yse/84152
Subject: absorption current
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (495.5Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE 43

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2017-09-04T16:20:44Z
date available2017-09-04T16:20:44Z
date copyright03/06/2000 (R 2006)
date issued2006
identifier otherTLOHJBAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/84152
description abstractThis document describes a recommended procedure for measuring insulation resistance of armature and field windings in rotating machines rated 1 hp, 750 W or greater. It applies to synchronous machines, induction machines, dc machines, and synchronous condensers. It does not apply to fractional-horsepower machines.
The document also describes typical insulation resistance characteristics of rotating machine windings and how these characteristics indicate winding condition. It recommends minimum acceptable values of insulation resistance for ac and dc rotating machine windings.
Other IEEE standards that include information on insulation resistance measurement are listed in Clause 2.
languageEnglish
titleIEEE 43num
titleRecommended Practice for Testing Insulation Resistance of Rotating Machineryen
typestandard
page27
statusActive
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2006
contenttypefulltext
subject keywordsabsorption current
subject keywordsconduction current
subject keywordsdischarge current
subject keywordsgeometric capacitive current
subject keywordsinsulation resistance
subject keywordspolarization index
subject keywordssurface leakage current
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian