NASA-LLIS-0366
Lessons Learned - Infrared Astronomical Satellite (IRAS) Contamination Control Challenges
Year: 1995
Abstract: Abstract:
IRAS posed new challenges to contamination control due to the extremely low temperatures (3 degrees Kelvin) required to achieve successful low noise infrared signal detector operation in the focal plane assembly. The elaborate contamination control precautions listed in the lesson were believed critical to mission success.
IRAS posed new challenges to contamination control due to the extremely low temperatures (3 degrees Kelvin) required to achieve successful low noise infrared signal detector operation in the focal plane assembly. The elaborate contamination control precautions listed in the lesson were believed critical to mission success.
Subject: Cryogenic Systems
Show full item record
| contributor author | NASA - National Aeronautics and Space Administration (NASA) | |
| date accessioned | 2017-09-04T16:22:26Z | |
| date available | 2017-09-04T16:22:26Z | |
| date copyright | 01/13/1995 | |
| date issued | 1995 | |
| identifier other | TQAEQCAAAAAAAAAA.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/85798 | |
| description abstract | Abstract: IRAS posed new challenges to contamination control due to the extremely low temperatures (3 degrees Kelvin) required to achieve successful low noise infrared signal detector operation in the focal plane assembly. The elaborate contamination control precautions listed in the lesson were believed critical to mission success. | |
| language | English | |
| title | NASA-LLIS-0366 | num |
| title | Lessons Learned - Infrared Astronomical Satellite (IRAS) Contamination Control Challenges | en |
| type | standard | |
| page | 3 | |
| status | Active | |
| tree | NASA - National Aeronautics and Space Administration (NASA):;1995 | |
| contenttype | fulltext | |
| subject keywords | Cryogenic Systems | |
| subject keywords | Cryogenics |