API TR 2569

Evaporative Loss from Closed-vent Internal Floating-roof Storage Tanks

Organization:
API - American Petroleum Institute
Year: 2008

Abstract: INTRODUCTION
This report addresses evaporative loss from internal floating-roof tanks (IFRTs) with closed vents, a subject not currently addressed by API. Nomenclature is provided in Appendix A.
The API Manual of Petroleum Measurement Standards Chapter 19, Section 1 (19.1) addresses evaporative loss from fixed-roof tanks, and specifically excludes fixed-roof tanks that have an internal floating roof (19.1.1.1).
The API Manual of Petroleum Measurement Standards Chapter 19, Section 2 (19.2) addresses evaporative loss from freely-vented internal floating-roof tanks, and specifically excludes "closed internal floating-roof tanks (that is, tanks vented only through a pressure-vacuum relief vent, blanketed with an inert gas, vented to a vapor processing unit, or otherwise restricted from being freely vented)" (1d).
URI: https://yse.yabesh.ir/std/handle/yse/87124
Collections :
  • API - American Petroleum Institute
  • Download PDF : (619.1Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    API TR 2569

Show full item record

contributor authorAPI - American Petroleum Institute
date accessioned2017-09-04T16:23:44Z
date available2017-09-04T16:23:44Z
date copyright08/01/2008
date issued2008
identifier otherTTMYGCAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/87124
description abstractINTRODUCTION
This report addresses evaporative loss from internal floating-roof tanks (IFRTs) with closed vents, a subject not currently addressed by API. Nomenclature is provided in Appendix A.
The API Manual of Petroleum Measurement Standards Chapter 19, Section 1 (19.1) addresses evaporative loss from fixed-roof tanks, and specifically excludes fixed-roof tanks that have an internal floating roof (19.1.1.1).
The API Manual of Petroleum Measurement Standards Chapter 19, Section 2 (19.2) addresses evaporative loss from freely-vented internal floating-roof tanks, and specifically excludes "closed internal floating-roof tanks (that is, tanks vented only through a pressure-vacuum relief vent, blanketed with an inert gas, vented to a vapor processing unit, or otherwise restricted from being freely vented)" (1d).
languageEnglish
titleAPI TR 2569num
titleEvaporative Loss from Closed-vent Internal Floating-roof Storage Tanksen
typestandard
page38
statusActive
treeAPI - American Petroleum Institute:;2008
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian