NAVY - SH - Naval Sea Systems Command (Ship Systems): Recent submissions
Now showing items 1301-1320 of 2792
-
MIL-E-21562E
Abstract: This specification covers nickel, nickel alloy and copper-nickel alloy bare welding electrodes and rods for use with the submerged arc (when used with a neutral flux), gas metal-arc (GMA) and gas tungsten-arc (GTA) welding ...Subject(s) : Alloy identity , Gas metal-arc , Gas tungsten-arc , Winding , -
MIL-PRF-24139A
Abstract: This specification covers one grade of grease for multipurpose usage in applications requiring water resistance. It is to be used at temperatures ranging from 0 degrees Fahrenheit (°F) to 230°F (110 degrees Celsius ... -
MIL-PRF-32232
Abstract: This performance specification covers Right Angle Offset (RAO) universal joints designed to transmit up to 18,000 inch-pounds of torque between misaligned and/or offset shafts. RAO universal joints are double universal ...Subject(s) : Gear box , Pin-and-cube , Remote operating gear , ROG , -
MIL-C-22249/5A
Abstract: This specification is approved for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by all Departments and Agencies of the Department of Defense.
The requirements for acquiring ... -
MIL-DTL-24704/1B
Abstract: This specification sheet covers the requirements for four bolt square socket weld flanges for use in 3000 pounds per square inch (lb/in2) hydraulic systems. -
MIL-C-24629
Abstract: This specification establishes the performance, design, and test requirements for a computer-controlled, automatic switching service for shipboard interior voice communications and distribution, henceforth referred to as ... -
A-A-50607
Abstract: Intended Use: This Commercial Item Description covers a dry suit to keep rescue swimmers dry during rescue operations. -
MIL-D-3263B
Abstract: This specification covers desiccant containers and their storage cases which are suitable for the static dehumidification of small, enclosed spaces, and which can be readily reactivated. Intended Use: The ...Subject(s) : Container , Dehumidification , Desiccant , Reactivation , -
MIL-H-24135/6A
Abstract: This specification covers synthetic rubber hoses, reinforced with two braids of wire or two spiral and one wire braid in sizes -4 through -32 for high pressure phosphate ester based fluids. Intended Use: ...Subject(s) : Synthetic lubricants , -
MIL-C-15430J
Abstract: This specification covers steam condensers for Naval Shipboard applications.
Condensers shall be of the following types and classes as specified (see 6.1.1).Type I - For main propulsion turbines ...

درباره ما