Light Water Reactor Coolant Pressure Boundary Leak Detection

contributor authorISA - International Society of Automation
date accessioned2017-09-04T16:30:51Z
date available2017-09-04T16:30:51Z
date copyright01/01/1982
date issued1982
identifier otherUMYNCAAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/94214
description abstractThis standard covers identification and quantitative measurement of reactor coolant system leakage in light water cooled power reactors. Leak detection for gas and liquid metal cooled reactors and for containment building structures surrounding the reactor coolant pressure boundary is not covered in this standard.
Purpose
The purpose of this standard is to standardize criteria, methods, and procedures for assuring the design and operational adequacy of reactor coolant pressure boundary leak detection systems used in light water cooled nuclear power plants. A further objective is to encourage design improvements yielding increased utility and reliability of reactor coolant leakage detection systems.
languageEnglish
titleISA 67.03num
titleLight Water Reactor Coolant Pressure Boundary Leak Detectionen
typestandard
page46
statusActive
treeISA - International Society of Automation:;1982
contenttypefulltext