• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • NFPA - (NFPA) - National Fluid Power Association
  • View Item
  •   YSE
  • Industrial Standards
  • NFPA - (NFPA) - National Fluid Power Association
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

NFPA 496

Standard for Purged and Pressurized Enclosures for Electrical Equipment - Effective Date: 12/17/2012

Organization:
NFPA - (NFPA) - National Fluid Power Association
Year: 2013

Abstract: This standard applies to purging and pressurizing for the following:
(1) Electrical equipment located in areas classified as hazardous by Article 500 or Article 505 of NFPA 70
(2) Electrical equipment containing sources of flammable vapors or gases and located in either classified or unclassified areas
(3) Control rooms or buildings located in areas classified as hazardous by Article 500 or Article 505 of NFPA 70
(4) Analyzer rooms containing sources of flammable vapors or gases and located in areas classified as hazardous by Article 500 or Article 505 of NFPA 70
This standard does not apply to electrical equipment located in:
(1) Areas classified as Class I, Zone 0
(2) Areas classified as Class III
(3) Areas where flammable liquids may be splashed or spilled on the electrical equipment
Purpose.
This standard provides information on the methods for purging and pressurizing enclosures to prevent ignition of a flammable atmosphere. Such an atmosphere may be introduced into the enclosure by a surrounding external atmosphere or by an internal source. By these means, electrical equipment that is not otherwise acceptable for a flammable atmosphere may be utilized in accordance with Article 500 or Article 505 of NFPA 70.
URI: http://yse.yabesh.ir/std/handle/yse/12321
Collections :
  • NFPA - (NFPA) - National Fluid Power Association
  • Download PDF : (403.9Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NFPA 496

Show full item record

contributor authorNFPA - (NFPA) - National Fluid Power Association
date accessioned2017-09-04T15:13:39Z
date available2017-09-04T15:13:39Z
date copyright2013.01.01
date issued2013
identifier otherMAUJBFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/12321
description abstractThis standard applies to purging and pressurizing for the following:
(1) Electrical equipment located in areas classified as hazardous by Article 500 or Article 505 of NFPA 70
(2) Electrical equipment containing sources of flammable vapors or gases and located in either classified or unclassified areas
(3) Control rooms or buildings located in areas classified as hazardous by Article 500 or Article 505 of NFPA 70
(4) Analyzer rooms containing sources of flammable vapors or gases and located in areas classified as hazardous by Article 500 or Article 505 of NFPA 70
This standard does not apply to electrical equipment located in:
(1) Areas classified as Class I, Zone 0
(2) Areas classified as Class III
(3) Areas where flammable liquids may be splashed or spilled on the electrical equipment
Purpose.
This standard provides information on the methods for purging and pressurizing enclosures to prevent ignition of a flammable atmosphere. Such an atmosphere may be introduced into the enclosure by a surrounding external atmosphere or by an internal source. By these means, electrical equipment that is not otherwise acceptable for a flammable atmosphere may be utilized in accordance with Article 500 or Article 505 of NFPA 70.
languageEnglish
titleNFPA 496num
titleStandard for Purged and Pressurized Enclosures for Electrical Equipment - Effective Date: 12/17/2012en
typestandard
page25
statusActive
treeNFPA - (NFPA) - National Fluid Power Association:;2013
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian