ACI 350.1M

Specification for Tightness Testing of Environmental Engineering Concrete Containment Structures (ACI 350.1M-10) and Commentary

Organization:
ACI - American Concrete Institute
Year: 2010

Abstract: Work specified—This Specification covers tightness testing of liquid and gaseous environmental containment structures designed to resist liquid or gaseous loads. Provisions of this Specification shall govern except where other provisions are specified in Contract Documents.
These test methods are for the tightness testing of concrete environmental engineering liquid and gaseous containment structures. The included tests are:
(a)Hydrostatic tightness test for open or covered containment structures.
(b)Surcharged hydrostatic tightness test for closed containment structures.
(c)Pneumatic tightness test for closed containment structures.
(d) Combination hydrostatic-pneumatic tightness test for closed containment structures.
The tightness testing procedures and requirements contained herein are applicable to reservoirs, basins, and tanks constructed of concrete or a combination of concrete and other materials. Preparatory items indicated are required, unless otherwise specified, but the waiver of such items shall not change the test criteria.
Each cell of multi-cell containment structures shall be considered a single containment structure and tested individually unless otherwise permitted.
The hydrostatic tightness testing procedures and requirements herein are also applicable for tightness testing of open concrete liquid transmission structures such as castin- place concrete channels and conduits.
The hydrostatic tightness testing procedures and requirements herein, where applicable, can be used for tightness testing of concrete paved structures, such as channels and impoundments.
Work not specified—These provisions are not intended for hazardous material primary or secondary containment structures, cryogenic storage structures, highpressure gas tanks, or miscellaneous precast concrete structures such as culverts, pipes, and manholes.
URI: http://yse.yabesh.ir/std/handle/yse/123451
Subject: containment structures
Collections :
  • ACI - American Concrete Institute
  • Download PDF : (156.7Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ACI 350.1M

Show full item record

contributor authorACI - American Concrete Institute
date accessioned2017-09-04T16:59:58Z
date available2017-09-04T16:59:58Z
date copyright01/01/2010
date issued2010
identifier otherXNJEFEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/123451
description abstractWork specified—This Specification covers tightness testing of liquid and gaseous environmental containment structures designed to resist liquid or gaseous loads. Provisions of this Specification shall govern except where other provisions are specified in Contract Documents.
These test methods are for the tightness testing of concrete environmental engineering liquid and gaseous containment structures. The included tests are:
(a)Hydrostatic tightness test for open or covered containment structures.
(b)Surcharged hydrostatic tightness test for closed containment structures.
(c)Pneumatic tightness test for closed containment structures.
(d) Combination hydrostatic-pneumatic tightness test for closed containment structures.
The tightness testing procedures and requirements contained herein are applicable to reservoirs, basins, and tanks constructed of concrete or a combination of concrete and other materials. Preparatory items indicated are required, unless otherwise specified, but the waiver of such items shall not change the test criteria.
Each cell of multi-cell containment structures shall be considered a single containment structure and tested individually unless otherwise permitted.
The hydrostatic tightness testing procedures and requirements herein are also applicable for tightness testing of open concrete liquid transmission structures such as castin- place concrete channels and conduits.
The hydrostatic tightness testing procedures and requirements herein, where applicable, can be used for tightness testing of concrete paved structures, such as channels and impoundments.
Work not specified—These provisions are not intended for hazardous material primary or secondary containment structures, cryogenic storage structures, highpressure gas tanks, or miscellaneous precast concrete structures such as culverts, pipes, and manholes.
languageEnglish
titleACI 350.1Mnum
titleSpecification for Tightness Testing of Environmental Engineering Concrete Containment Structures (ACI 350.1M-10) and Commentaryen
typestandard
page19
statusActive
treeACI - American Concrete Institute:;2010
contenttypefulltext
subject keywordscontainment structures
subject keywordshydrostatic
subject keywordsleakage
subject keywordspneumatic
subject keywordsreservoirs
subject keywordstests
subject keywordstightness
subject keywordstightness criteria.