NFPA 86

Standard for Ovens and Furnaces - Effective Date: 5/19/2014

Organization:
NFPA - (NFPA) - National Fluid Power Association
Year: 2015

Abstract: This standard shall apply to Class A, Class B, Class C, and Class D ovens, dryers, and furnaces; thermal oxidizers; and any other heated enclosure used for processing of materials and related equipment.
The terms ovens, dryers, and furnaces are used interchangeably and shall also apply to other heated enclosures used for processing of materials.
Within the scope of this standard, a Class A, Class B, or Class C oven is any heated enclosure operating at approximately atmospheric pressure and used for commercial and industrial processing of materials.
AClassAoven shall be permitted to utilize a low-oxygen atmosphere.
This standard shall apply to bakery ovens and Class A ovens, in all respects, and where reference is made to ANSI Z50.1, Bakery Equipment — Safety Requirements, those requirements shall apply to bakery oven construction and safety.
This standard shall apply to atmosphere generators and atmosphere supply systems serving Class C furnaces and to furnaces with integral quench tanks or molten salt baths.
This standard shall apply to Class D ovens and furnaces operating above ambient temperatures to over 5000°F (2760°C) and at pressures normally below atmospheric to 10−8 torr (1.33 × 10−6 Pa).
This standard shall not apply to the following: (1)*Coal or other solid fuel–firing systems
(2) Listed equipment with a heating system(s) that supplies a total input not exceeding 150,000 Btu/hr (44 kW)
(3) Fired heaters in petroleum refineries and petrochemical facilities that are designed and installed in accordance with API STD 560, Fired Heaters for General Refinery Services, 2007; API RP 556, Instrumentation and Control Systems for Fired Heaters and Steam Generators, 1997; and API RP 2001, Fire Protection in Refineries, 2005.
(4) Fluid heaters as defined in NFPA 87, Recommended Practice for Fluid Heaters
(5) Electric arc furnaces and submerged arc furnaces
Purpose. This standard provides the requirements for furnaces to minimize the fire and explosion hazards that can endanger the furnace, the building, or personnel.
URI: http://yse.yabesh.ir/std/handle/yse/130551
Collections :
  • NFPA - (NFPA) - National Fluid Power Association
  • Download PDF : (4.981Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NFPA 86

Show full item record

contributor authorNFPA - (NFPA) - National Fluid Power Association
date accessioned2017-09-04T17:07:00Z
date available2017-09-04T17:07:00Z
date copyright2015.01.01
date issued2015
identifier otherYGPLIFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/130551
description abstractThis standard shall apply to Class A, Class B, Class C, and Class D ovens, dryers, and furnaces; thermal oxidizers; and any other heated enclosure used for processing of materials and related equipment.
The terms ovens, dryers, and furnaces are used interchangeably and shall also apply to other heated enclosures used for processing of materials.
Within the scope of this standard, a Class A, Class B, or Class C oven is any heated enclosure operating at approximately atmospheric pressure and used for commercial and industrial processing of materials.
AClassAoven shall be permitted to utilize a low-oxygen atmosphere.
This standard shall apply to bakery ovens and Class A ovens, in all respects, and where reference is made to ANSI Z50.1, Bakery Equipment — Safety Requirements, those requirements shall apply to bakery oven construction and safety.
This standard shall apply to atmosphere generators and atmosphere supply systems serving Class C furnaces and to furnaces with integral quench tanks or molten salt baths.
This standard shall apply to Class D ovens and furnaces operating above ambient temperatures to over 5000°F (2760°C) and at pressures normally below atmospheric to 10−8 torr (1.33 × 10−6 Pa).
This standard shall not apply to the following: (1)*Coal or other solid fuel–firing systems
(2) Listed equipment with a heating system(s) that supplies a total input not exceeding 150,000 Btu/hr (44 kW)
(3) Fired heaters in petroleum refineries and petrochemical facilities that are designed and installed in accordance with API STD 560, Fired Heaters for General Refinery Services, 2007; API RP 556, Instrumentation and Control Systems for Fired Heaters and Steam Generators, 1997; and API RP 2001, Fire Protection in Refineries, 2005.
(4) Fluid heaters as defined in NFPA 87, Recommended Practice for Fluid Heaters
(5) Electric arc furnaces and submerged arc furnaces
Purpose. This standard provides the requirements for furnaces to minimize the fire and explosion hazards that can endanger the furnace, the building, or personnel.
languageEnglish
titleNFPA 86num
titleStandard for Ovens and Furnaces - Effective Date: 5/19/2014en
typestandard
page150
statusActive
treeNFPA - (NFPA) - National Fluid Power Association:;2015
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian