NFPA 270

Standard Test Method for Measurement of Smoke Obscuration Using a Conical Radiant Source in a Single Closed Chamber - Effective Date: 12/17/2012

Organization:
NFPA - (NFPA) - National Fluid Power Association
Year: 2013

Abstract: This shall be a fire-test-response standard.
This test method shall provide a means of measuring smoke obscuration resulting from subjecting essentially flat materials, products, or assemblies (including surface finishes) not exceeding 25 mm in thickness to specified levels of thermal irradiance from a conical heater, in a single closed chamber, in the absence or presence of a pilot flame, and when placed in a horizontal orientation.
The principal fire-test-response characteristic obtained from this test method shall be the specific optical density of smoke from the specimens tested, which is obtained as a function of time, for a period of 10 minutes.
Other fire-test-response characteristics shall also be permitted to be determined.
An optional fire-test-response characteristic measurable with this test method shall be the mass optical density, which is the specific optical density of smoke divided by the mass lost by the specimens during the test.
This test method shall be based on ISO 5659-2, Determination of Specific Optical Density by a Single-Chamber Test, and shall provide equivalent results to ISO 5659-2.
The fire-test-response characteristics obtained from this test shall be specific to the specimen tested, in the form and thickness tested, and shall not be inherent properties of the material, product, or assembly.
This test method shall not provide information on the fire performance of the test specimens under fire conditions other than those conditions specified in this test method.
This standard shall measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions but shall not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.
Fire testing of products and materials is inherently hazardous, and safeguards for personnel and property shall be employed in conducting these tests.
This standard shall not purport to address all of the safety problems, if any, associated with its use.
It shall be the responsibility of the user of this standard to establish the necessary safety and health practices and determine the applicability of regulatory limitations prior to use
URI: http://yse.yabesh.ir/std/handle/yse/155631
Collections :
  • NFPA - (NFPA) - National Fluid Power Association
  • Download PDF : (510.4Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NFPA 270

Show full item record

contributor authorNFPA - (NFPA) - National Fluid Power Association
date accessioned2017-09-04T17:32:42Z
date available2017-09-04T17:32:42Z
date copyright2013.01.01
date issued2013
identifier otherDAUJBFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/155631
description abstractThis shall be a fire-test-response standard.
This test method shall provide a means of measuring smoke obscuration resulting from subjecting essentially flat materials, products, or assemblies (including surface finishes) not exceeding 25 mm in thickness to specified levels of thermal irradiance from a conical heater, in a single closed chamber, in the absence or presence of a pilot flame, and when placed in a horizontal orientation.
The principal fire-test-response characteristic obtained from this test method shall be the specific optical density of smoke from the specimens tested, which is obtained as a function of time, for a period of 10 minutes.
Other fire-test-response characteristics shall also be permitted to be determined.
An optional fire-test-response characteristic measurable with this test method shall be the mass optical density, which is the specific optical density of smoke divided by the mass lost by the specimens during the test.
This test method shall be based on ISO 5659-2, Determination of Specific Optical Density by a Single-Chamber Test, and shall provide equivalent results to ISO 5659-2.
The fire-test-response characteristics obtained from this test shall be specific to the specimen tested, in the form and thickness tested, and shall not be inherent properties of the material, product, or assembly.
This test method shall not provide information on the fire performance of the test specimens under fire conditions other than those conditions specified in this test method.
This standard shall measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions but shall not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.
Fire testing of products and materials is inherently hazardous, and safeguards for personnel and property shall be employed in conducting these tests.
This standard shall not purport to address all of the safety problems, if any, associated with its use.
It shall be the responsibility of the user of this standard to establish the necessary safety and health practices and determine the applicability of regulatory limitations prior to use
languageEnglish
titleNFPA 270num
titleStandard Test Method for Measurement of Smoke Obscuration Using a Conical Radiant Source in a Single Closed Chamber - Effective Date: 12/17/2012en
typestandard
page29
statusActive
treeNFPA - (NFPA) - National Fluid Power Association:;2013
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian