Search
Now showing items 11-20 of 636
ACI 351.2R: Report on Foundations for Static Equipment
Abstract: This report is limited in scope to the engineering and construction of static equipment foundations. Static equipment, as used herein, refers to industrial equipment that does not contain significant moving parts, or that ...
ACI 343.1R: Guide for the Analysis and Design of Reinforced and Prestressed Concrete Guideway Structures
Abstract: Design criteria specifically recognize the unique features of concrete transit guideways—namely, guideway/vehicle interaction, rail/structure interaction, special fatigue requirements, and aesthetic requirements in ...
ACI 506.2M: Specification for Shotcrete
Abstract: Work specified—This Reference Specification covers the requirements for shotcrete as specified by the Architect/ Engineer. Included are the requirements for materials; proportioning; and application of structural and nonstructural shotcrete, including structural and nonstructural fiberreinforced shotcrete.
Unitsâ€&...
Unitsâ€&...
ACI 358.1R: Analysis and Design of Reinforced and Prestressed-Concrete Guideway Structures
Abstract: These recommendations are intended to provide public agencies, consultants, and other interested personnel with comprehensive criteria for the design and analysis of concrete guideways for public transit systems. They ...
ACI 550.2R: Design Guide for Connections in Precast Jointed Systems
Abstract: This guide provides information on the characteristics and design of connections between precast concrete components and between precast components and cast-in-place construction. The proper detailing and design of precast ...
ACI 364.2T: Increasing Shear Capacity Within Existing Reinforced Concrete Structures
Abstract: Purpose and scope
The purpose of this report is to provide a source of information on the evaluation of concrete structures (except those subjected to seismic effects) prior to rehabilitation. This is of particular importance since there is a substantial difference between the complexity of rehabilitation design, as compared wi...
The purpose of this report is to provide a source of information on the evaluation of concrete structures (except those subjected to seismic effects) prior to rehabilitation. This is of particular importance since there is a substantial difference between the complexity of rehabilitation design, as compared wi...
ACI 318: Building Code Requirements for Structural Concrete and Commentary on Building Code Requirements for Structural Concrete
Abstract: PREFACE TO ACI 318-14
The "Building Code Requirements for Structural Concrete" ("Code") provides minimum requirements for the materials, design, and detailing of structural concrete buildings and, where applicable, nonbuilding structures. This Code addresses structural systems, members, and connections, including cast-in-place, precast, plain, ...
The "Building Code Requirements for Structural Concrete" ("Code") provides minimum requirements for the materials, design, and detailing of structural concrete buildings and, where applicable, nonbuilding structures. This Code addresses structural systems, members, and connections, including cast-in-place, precast, plain, ...
ACI 330.1: Specification for Unreinforced Concrete Parking Lots
Abstract: This specification covers requirements for the construction of unreinforced concrete parking lots on grade, including attached and integral curbs.
ACI 372R: Design and Construction of Circular Wire- and Strand- Wrapped Prestressed Concrete Structures
Abstract: The recommendations supplement the general requirements for reinforced concrete and prestressed concrete design and construction given in AC1 318-99, AC1 350-01, and AC1 301. Design and construction recommendations cover the following elements or components of circularwrapped prestressed concrete structures:
I. Floors
Reinforced concrete
I. Floors
Reinforced concrete
ACI 423.7: Specification for Unbonded Single-Strand Tendon Materials and Commentary
Abstract: This Specification provides materials criteria and fabrication requirements for unbonded single-strand tendons used in nonaggressive and aggressive environments.
This Specification is not intended to apply to nonstructural elements and applications, which might include topping slabs, waterproofing slabs-on-fill, and posttensioning used only for...
This Specification is not intended to apply to nonstructural elements and applications, which might include topping slabs, waterproofing slabs-on-fill, and posttensioning used only for...