NASA-LLIS-1226

Lessons Learned - Stripping of insulation from small-gauge wires

Organization:
NASA - National Aeronautics and Space Administration (NASA)
Year: 1998

Abstract: Description of Driving Event:
Qualification test failures of RM2679 transformers were discovered after vibration screening. Posttest analysis of the failed transformers revealed there were gaps between internal contacts. Further analysis revealed that wires had broken off where the transformer coil wire is soldered to larger terminals.
Root cause: Nicks were discovered on the coil winding wire near its attachment point. Further investigation determined that assembly personnel were using mechanical strippers to strip the coating off the ends of the wire. These nicks became stress concentrators leading to subsequent failure during vibration testing.
URI: http://yse.yabesh.ir/std/handle/yse/178164
Subject: Flight Equipment
Collections :
  • NASA - National Aeronautics and Space Administration (NASA)
  • Download PDF : (13.26Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NASA-LLIS-1226

Show full item record

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T17:55:01Z
date available2017-09-04T17:55:01Z
date copyright36089
date issued1998
identifier otherFIVEQCAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/178164
description abstractDescription of Driving Event:
Qualification test failures of RM2679 transformers were discovered after vibration screening. Posttest analysis of the failed transformers revealed there were gaps between internal contacts. Further analysis revealed that wires had broken off where the transformer coil wire is soldered to larger terminals.
Root cause: Nicks were discovered on the coil winding wire near its attachment point. Further investigation determined that assembly personnel were using mechanical strippers to strip the coating off the ends of the wire. These nicks became stress concentrators leading to subsequent failure during vibration testing.
languageEnglish
titleNASA-LLIS-1226num
titleLessons Learned - Stripping of insulation from small-gauge wiresen
typestandard
page2
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;1998
contenttypefulltext
subject keywordsFlight Equipment
subject keywordsGround Equipment
subject keywordsHardware
subject keywordsHuman Resources & Education
subject keywordsIndustrial Operations
subject keywordsParts Materials & Processes
subject keywordsSafety & Mission Assurance
subject keywordsTest & Verification
DSpace software copyright © 2017-2020  DuraSpace