NFPA 415

Standard on Airport Terminal Buildings, Fueling Ramp Drainage, and Loading Walkways - Effective Date: 06/18/2012

Organization:
NFPA - (NFPA) - National Fluid Power Association
Year: 2013

Abstract: This standard specifies the minimum fire protection requirements for the construction and protection of airport terminal buildings. It specifies the minimum requirements for the design and maintenance of the drainage system of an aircraft fueling ramp to control the flow of fuel that can be spilled on a ramp and to minimize the resulting possible danger. In addition, it contains the minimum requirements for the design, construction, and fire protection of aircraft loading walkways between the terminal building and aircraft.
Purpose. The purpose of this standard is to provide a reasonable degree of protection for life and property from fire at airport terminal complexes.
Requirements applicable to ramp drainage systems are intended to limit the fire hazard from fuel spillage in the following ways:
(1) Controlling the spread of a fuel spill to limit exposure to buildings, aircraft loading walkways, concourses, or elevated structures in order to prevent the fuel's liquid or vapors from reaching a source of ignition or accumulating within structures
2) Limiting the spread of the fuel spill over the ramp surface and preventing the transmission of vapors by the drainage system from exposing aircraft or other equipment parked or operating on the ramp
The purpose of this standard is also to specify minimum criteria for fire protection of aircraft loading walkways that can serve as egress routes from aircraft in the event that a fire caused by a flammable liquid spill on the airport ramp exposes the walkway and the aircraft.
Application. It is not intended that the provisions of this document be applied to facilities, equipment, structures, or installations that existed or were approved for construction or installation prior to the effective date of the document, except in those cases where it is determined by the authority having jurisdiction that the existing situation involves a distinct hazard to life or adjacent property.
URI: http://yse.yabesh.ir/std/handle/yse/181837
Collections :
  • NFPA - (NFPA) - National Fluid Power Association
  • Download PDF : (1.026Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NFPA 415

Show full item record

contributor authorNFPA - (NFPA) - National Fluid Power Association
date accessioned2017-09-04T17:58:44Z
date available2017-09-04T17:58:44Z
date copyright2013.01.01
date issued2013
identifier otherFSGLXEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/181837
description abstractThis standard specifies the minimum fire protection requirements for the construction and protection of airport terminal buildings. It specifies the minimum requirements for the design and maintenance of the drainage system of an aircraft fueling ramp to control the flow of fuel that can be spilled on a ramp and to minimize the resulting possible danger. In addition, it contains the minimum requirements for the design, construction, and fire protection of aircraft loading walkways between the terminal building and aircraft.
Purpose. The purpose of this standard is to provide a reasonable degree of protection for life and property from fire at airport terminal complexes.
Requirements applicable to ramp drainage systems are intended to limit the fire hazard from fuel spillage in the following ways:
(1) Controlling the spread of a fuel spill to limit exposure to buildings, aircraft loading walkways, concourses, or elevated structures in order to prevent the fuel's liquid or vapors from reaching a source of ignition or accumulating within structures
2) Limiting the spread of the fuel spill over the ramp surface and preventing the transmission of vapors by the drainage system from exposing aircraft or other equipment parked or operating on the ramp
The purpose of this standard is also to specify minimum criteria for fire protection of aircraft loading walkways that can serve as egress routes from aircraft in the event that a fire caused by a flammable liquid spill on the airport ramp exposes the walkway and the aircraft.
Application. It is not intended that the provisions of this document be applied to facilities, equipment, structures, or installations that existed or were approved for construction or installation prior to the effective date of the document, except in those cases where it is determined by the authority having jurisdiction that the existing situation involves a distinct hazard to life or adjacent property.
languageEnglish
titleNFPA 415num
titleStandard on Airport Terminal Buildings, Fueling Ramp Drainage, and Loading Walkways - Effective Date: 06/18/2012en
typestandard
page24
statusActive
treeNFPA - (NFPA) - National Fluid Power Association:;2013
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian