Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components - Effective Date: 1/2/2012
Organization:
NFPA - (NFPA) - National Fluid Power Association
Year: 2012
Abstract: This standard provides a test method for determining the fire propagation characteristics of exterior non-load-bearing wall assemblies and panels used as components of curtain wall assemblies, that are constructed using combustible materials or that incorporate combustible components, and that are intended to be installed on buildings required to have exterior walls of noncombustible construction.
The fire propagation characteristics are determined for post-flashover fires of interior origin.
Purpose. The purpose of this standard is to provide a standardized fire test procedure for evaluating the suitability of exterior non-load-bearing wall assemblies and panels used as components of curtain wall assemblies that are constructed using combustible materials or that incorporate combustible components for installation on buildings where the exterior walls are required to be noncombustible.
The fire propagation characteristics are determined for post-flashover fires of interior origin.
Purpose. The purpose of this standard is to provide a standardized fire test procedure for evaluating the suitability of exterior non-load-bearing wall assemblies and panels used as components of curtain wall assemblies that are constructed using combustible materials or that incorporate combustible components for installation on buildings where the exterior walls are required to be noncombustible.
Collections
:
Show full item record
| contributor author | NFPA - (NFPA) - National Fluid Power Association | |
| date accessioned | 2017-09-04T18:05:09Z | |
| date available | 2017-09-04T18:05:09Z | |
| date copyright | 2012.01.01 | |
| date issued | 2012 | |
| identifier other | ACGSTEAAAAAAAAAA.pdf | |
| identifier uri | http://yse.yabesh.ir/std/handle/yse/188130 | |
| description abstract | This standard provides a test method for determining the fire propagation characteristics of exterior non-load-bearing wall assemblies and panels used as components of curtain wall assemblies, that are constructed using combustible materials or that incorporate combustible components, and that are intended to be installed on buildings required to have exterior walls of noncombustible construction. The fire propagation characteristics are determined for post-flashover fires of interior origin. Purpose. The purpose of this standard is to provide a standardized fire test procedure for evaluating the suitability of exterior non-load-bearing wall assemblies and panels used as components of curtain wall assemblies that are constructed using combustible materials or that incorporate combustible components for installation on buildings where the exterior walls are required to be noncombustible. | |
| language | English | |
| title | NFPA 285 | num |
| title | Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components - Effective Date: 1/2/2012 | en |
| type | standard | |
| page | 30 | |
| status | Active | |
| tree | NFPA - (NFPA) - National Fluid Power Association:;2012 | |
| contenttype | fulltext |