NFPA 110

Standard for Emergency and Standby Power Systems - Effective Date: 06/18/2012

Organization:
NFPA - (NFPA) - National Fluid Power Association
Year: 2013

Abstract: This standard contains requirements covering the performance of emergency and standby power systems providing an alternate source of electrical power to loads in buildings and facilities in the event that the primary power source fails.
Power systems covered in this standard include power sources, transfer equipment, controls, supervisory equipment, and all related electrical and mechanical auxiliary and accessory equipment needed to supply electrical power to the load terminals of the transfer equipment.
This standard covers installation, maintenance, operation, and testing requirements as they pertain to the performance of the emergency power supply system (EPSS).
This standard does not cover the following:
(1) Application of the EPSS
(2) Emergency lighting unit equipment
(3) Distribution wiring
(4) Utility service when such service is permitted as the EPSS
(5) Parameters for stored energy devices
(6) The equipment of systems that are not classed as Level 1 or Level 2 systems in accordance with Chapter 4 of this standard
This standard does not establish criteria for stored energy systems.
The selection of any of the following is not within the scope of this standard:
(1) Specific buildings or facilities, or both, requiring an EPSS
(2) Specific loads to be served by the EPSS
(3)*Assignment of type, class, or level to any specific load
Purpose. This standard contains performance requirements for an EPSS.
It is the role of other NFPA standards to specify which occupancies require an EPSS and the applicable level, type, and class. This standard does not specify where an EPSS is required.
This standard also is intended to provide guidance for inspectors, designers, installers, manufacturers, and users of EPSSs and to serve as a vehicle for communication between the parties involved. It is not intended as a design manual.
Compliance with this standard is not intended to exempt the parties involved from their respective responsibilities for the design, installation, maintenance, performance, or compliance with other applicable standards and codes.
Application. This document applies to new installations of EPSSs, except that the requirements of Chapter 8 shall apply to new and existing systems. Existing systems shall not be required to be modified to conform, except where the authority having jurisdiction determines that nonconformity presents a distinct hazard to life.
Equivalency. Nothing in this standard is intended to prevent the use of systems, methods, or devices of equivalent or superior quality, strength, fire resistance, effectiveness, durability, and safety to those prescribed by this standard.
Technical documentation shall be submitted to the authority having jurisdiction to demonstrate equivalency.
The system, method, or device shall be approved for the intended purpose by the authority having jurisdiction.
URI: http://yse.yabesh.ir/std/handle/yse/199190
Collections :
  • NFPA - (NFPA) - National Fluid Power Association
  • Download PDF : (1.088Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NFPA 110

Show full item record

contributor authorNFPA - (NFPA) - National Fluid Power Association
date accessioned2017-09-04T18:16:20Z
date available2017-09-04T18:16:20Z
date copyright2013.01.01
date issued2013
identifier otherHMKOXEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/199190
description abstractThis standard contains requirements covering the performance of emergency and standby power systems providing an alternate source of electrical power to loads in buildings and facilities in the event that the primary power source fails.
Power systems covered in this standard include power sources, transfer equipment, controls, supervisory equipment, and all related electrical and mechanical auxiliary and accessory equipment needed to supply electrical power to the load terminals of the transfer equipment.
This standard covers installation, maintenance, operation, and testing requirements as they pertain to the performance of the emergency power supply system (EPSS).
This standard does not cover the following:
(1) Application of the EPSS
(2) Emergency lighting unit equipment
(3) Distribution wiring
(4) Utility service when such service is permitted as the EPSS
(5) Parameters for stored energy devices
(6) The equipment of systems that are not classed as Level 1 or Level 2 systems in accordance with Chapter 4 of this standard
This standard does not establish criteria for stored energy systems.
The selection of any of the following is not within the scope of this standard:
(1) Specific buildings or facilities, or both, requiring an EPSS
(2) Specific loads to be served by the EPSS
(3)*Assignment of type, class, or level to any specific load
Purpose. This standard contains performance requirements for an EPSS.
It is the role of other NFPA standards to specify which occupancies require an EPSS and the applicable level, type, and class. This standard does not specify where an EPSS is required.
This standard also is intended to provide guidance for inspectors, designers, installers, manufacturers, and users of EPSSs and to serve as a vehicle for communication between the parties involved. It is not intended as a design manual.
Compliance with this standard is not intended to exempt the parties involved from their respective responsibilities for the design, installation, maintenance, performance, or compliance with other applicable standards and codes.
Application. This document applies to new installations of EPSSs, except that the requirements of Chapter 8 shall apply to new and existing systems. Existing systems shall not be required to be modified to conform, except where the authority having jurisdiction determines that nonconformity presents a distinct hazard to life.
Equivalency. Nothing in this standard is intended to prevent the use of systems, methods, or devices of equivalent or superior quality, strength, fire resistance, effectiveness, durability, and safety to those prescribed by this standard.
Technical documentation shall be submitted to the authority having jurisdiction to demonstrate equivalency.
The system, method, or device shall be approved for the intended purpose by the authority having jurisdiction.
languageEnglish
titleNFPA 110num
titleStandard for Emergency and Standby Power Systems - Effective Date: 06/18/2012en
typestandard
page45
statusActive
treeNFPA - (NFPA) - National Fluid Power Association:;2013
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian