UL SUBJECT 1699A
OUTLINE OF INVESTIGATION FOR OUTLET BRANCH CIRCUIT ARC-FAULT CIRCUIT-INTERRUPTERS - Issue 2
Organization:
UL - UL
Year: 2010
Abstract: These requirements cover arc-fault circuit-interrupters (AFCIs) of the outlet branch circuit type intended for use in dwelling units. These devices are intended to mitigate the effects of arcing faults that may pose a risk of fire ignition under certain conditions if the arcing persists.
These devices have a maximum rating of 20 A and are intended for use in 120-V ac, 60-HZ circuits.
These requirements are intended to be used with the Standard for Arc-Fault Circuit-Interrupters, UL 1699, as these requirements modify the requirements described in that standard.
Unless otherwise specified, when the term "arc-fault circuit-interrupter" or "AFCI" is used in this Outline, it refers to an arc-fault circuit-interrupter of the outlet branch circuit type, also known as an outlet branch circuit arc-fault circuit-interrupter (OBC AFCI).
These devices have a maximum rating of 20 A and are intended for use in 120-V ac, 60-HZ circuits.
These requirements are intended to be used with the Standard for Arc-Fault Circuit-Interrupters, UL 1699, as these requirements modify the requirements described in that standard.
Unless otherwise specified, when the term "arc-fault circuit-interrupter" or "AFCI" is used in this Outline, it refers to an arc-fault circuit-interrupter of the outlet branch circuit type, also known as an outlet branch circuit arc-fault circuit-interrupter (OBC AFCI).
Collections
:
-
Statistics
UL SUBJECT 1699A
Show full item record
| contributor author | UL - UL | |
| date accessioned | 2017-09-04T18:33:58Z | |
| date available | 2017-09-04T18:33:58Z | |
| date copyright | 03/17/2010 | |
| date issued | 2010 | |
| identifier other | JFJLQCAAAAAAAAAA.pdf | |
| identifier uri | http://yse.yabesh.ir/std/handle/yse/216163 | |
| description abstract | These requirements cover arc-fault circuit-interrupters (AFCIs) of the outlet branch circuit type intended for use in dwelling units. These devices are intended to mitigate the effects of arcing faults that may pose a risk of fire ignition under certain conditions if the arcing persists. These devices have a maximum rating of 20 A and are intended for use in 120-V ac, 60-HZ circuits. These requirements are intended to be used with the Standard for Arc-Fault Circuit-Interrupters, UL 1699, as these requirements modify the requirements described in that standard. Unless otherwise specified, when the term "arc-fault circuit-interrupter" or "AFCI" is used in this Outline, it refers to an arc-fault circuit-interrupter of the outlet branch circuit type, also known as an outlet branch circuit arc-fault circuit-interrupter (OBC AFCI). | |
| language | English | |
| title | UL SUBJECT 1699A | num |
| title | OUTLINE OF INVESTIGATION FOR OUTLET BRANCH CIRCUIT ARC-FAULT CIRCUIT-INTERRUPTERS - Issue 2 | en |
| type | standard | |
| page | 16 | |
| status | Active | |
| tree | UL - UL:;2010 | |
| contenttype | fulltext |