UL 1773

UL Standard for Safety Termination Boxes - Fifth Edition

Organization:
UL - UL
Year: 2011

Abstract: These requirements cover termination boxes rated 600 V or less that consist of lengths of bus bars, terminal strips, or terminal blocks with provision for wire connectors to accommodate incoming or outgoing conductors or both and are intended to be used in accordance with the National Electrical Code, NFPA 70. Termination boxes are investigated for use on the line or load side of service equipment.
The incoming and outgoing conductors may be routed through knockouts or openings in the box for cable, conduit, or electrical metallic tubing. The termination box may also have special openings to match with similar openings in other equipment such as meter sockets, panelboards, switch or circuit breaker enclosures, wireways, and the like.
These requirements also cover termination bases to be field installed in termination boxes and termination boxes in which termination bases are to be field installed.
This category covers mounting posts and pedestals rated 600 V ac or less intended to serve as a raceway for underground wiring that is being brought above grade to feed an outdoor electrical distribution device, such as a power outlet, panelboard, meter socket, circuit breaker enclosure or the like. They are intended to support the distribution device, which is installed either in the factory or in the field. They may contain electrical termination points for underground wiring and for wiring to the distribution device. 
These requirements do not cover equipment connected only by bus bars for both input and output circuits, nor equipment containing switching devices, relays, or overcurrent protective devices. These requirements also do not cover busway fittings known as "End Cable Tap Boxes" which are covered by the Standard for Busways, UL 857.
URI: http://yse.yabesh.ir/std/handle/yse/220142
Collections :
  • UL - UL
  • Download PDF : (496.2Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UL 1773

Show full item record

contributor authorUL - UL
date accessioned2017-09-04T18:38:23Z
date available2017-09-04T18:38:23Z
date copyright40847
date issued2011
identifier otherJPOFOEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/220142
description abstractThese requirements cover termination boxes rated 600 V or less that consist of lengths of bus bars, terminal strips, or terminal blocks with provision for wire connectors to accommodate incoming or outgoing conductors or both and are intended to be used in accordance with the National Electrical Code, NFPA 70. Termination boxes are investigated for use on the line or load side of service equipment.
The incoming and outgoing conductors may be routed through knockouts or openings in the box for cable, conduit, or electrical metallic tubing. The termination box may also have special openings to match with similar openings in other equipment such as meter sockets, panelboards, switch or circuit breaker enclosures, wireways, and the like.
These requirements also cover termination bases to be field installed in termination boxes and termination boxes in which termination bases are to be field installed.
This category covers mounting posts and pedestals rated 600 V ac or less intended to serve as a raceway for underground wiring that is being brought above grade to feed an outdoor electrical distribution device, such as a power outlet, panelboard, meter socket, circuit breaker enclosure or the like. They are intended to support the distribution device, which is installed either in the factory or in the field. They may contain electrical termination points for underground wiring and for wiring to the distribution device. 
These requirements do not cover equipment connected only by bus bars for both input and output circuits, nor equipment containing switching devices, relays, or overcurrent protective devices. These requirements also do not cover busway fittings known as "End Cable Tap Boxes" which are covered by the Standard for Busways, UL 857.
languageEnglish
titleUL 1773num
titleUL Standard for Safety Termination Boxes - Fifth Editionen
typestandard
page46
statusActive
treeUL - UL:;2011
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian