Abstract: This specification covers an ozone-resistant insulating compound for electrical wire and cables 14 AWG and larger. This compound consists substantially of a thermoplastic elastomer.
This type of insulation is suitable for continuous operation at conductor temperatures not exceeding 90 °C in dry locations and 75 °C in wet locations. Operating voltages are not to exceed 2000 V. The minimum installation temperature is −40 °C.
The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
In many instances the insulation material cannot be tested unless it has been formed around a conductor or cable. Therefore, tests are done on insulated wire or cable in this document solely to determine the relevant property of the insulation material and not to test the conductor or completed cable.
*A Summary of Changes section appears at the end of this standard.
This type of insulation is suitable for continuous operation at conductor temperatures not exceeding 90 °C in dry locations and 75 °C in wet locations. Operating voltages are not to exceed 2000 V. The minimum installation temperature is −40 °C.
The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
In many instances the insulation material cannot be tested unless it has been formed around a conductor or cable. Therefore, tests are done on insulated wire or cable in this document solely to determine the relevant property of the insulation material and not to test the conductor or completed cable.
*A Summary of Changes section appears at the end of this standard.
Subject: 90°C dry/75°C wet insulation
Collections
:
Show full item record
contributor author | ASTM - ASTM International | |
date accessioned | 2017-09-04T15:22:06Z | |
date available | 2017-09-04T15:22:06Z | |
date copyright | 39753 | |
date issued | 2008 | |
identifier other | NBBALCAAAAAAAAAA.pdf | |
identifier uri | http://yse.yabesh.ir/std/handle/yse/22121 | |
description abstract | This specification covers an ozone-resistant insulating compound for electrical wire and cables 14 AWG and larger. This compound consists substantially of a thermoplastic elastomer. This type of insulation is suitable for continuous operation at conductor temperatures not exceeding 90 °C in dry locations and 75 °C in wet locations. Operating voltages are not to exceed 2000 V. The minimum installation temperature is −40 °C. The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. In many instances the insulation material cannot be tested unless it has been formed around a conductor or cable. Therefore, tests are done on insulated wire or cable in this document solely to determine the relevant property of the insulation material and not to test the conductor or completed cable. *A Summary of Changes section appears at the end of this standard. | |
language | English | |
title | ASTM D4245 | num |
title | Standard Specification for Ozone-Resistant Thermoplastic Elastomer Insulation For Wire and Cable, 90 °C Dry/75 °C Wet Operation | en |
type | standard | |
page | 2 | |
status | Active | |
tree | ASTM - ASTM International:;2008 | |
contenttype | fulltext | |
subject keywords | 90°C dry/75°C wet insulation | |
subject keywords | ac voltage test | |
subject keywords | accelerated water absorption | |
subject keywords | dc voltage test | |
subject keywords | insulation | |
subject keywords | insulation resistance | |
subject keywords | ozone-resistant | |
subject keywords | thermoplastic elastomer | |
subject keywords | thermoplastic elastomer insulation |