UL 1998 BULLETIN

UL Standard for Safety Software in Programmable Components - COMMENTS DUE: May 19, 2011

Organization:
UL - UL
Year: 2011

Abstract: These requirements apply to non-networked embedded microprocessor software whose failure is capable of resulting in a risk of fire, electric shock, or injury to persons.
This is a reference standard in which the requirements are to be applied when specifically referenced by other standards or product safety requirements.
These requirements address the risks unique to product hardware controlled by software in programmable components.
These requirements are intended to supplement applicable product or component standards and requirements, and are not intended to serve as the sole basis for investigating the risk of fire, electric shock, or injury to persons.
These requirements are intended to address risks that occur in the software or in the process used to develop and maintain the software, such as the following:
a) Requirements conversion faults that cause differences between the specification for the programmable component and the software design;
b) Design faults such as incorrect software algorithms or interfaces;
c) Coding faults, including syntax, incorrect signs, endless loops, and other coding faults;
d) Timing faults that cause program execution to occur prematurely or late;
e) Microelectronic memory faults, such as memory failure, not enough memory, or memory overlap;
f) Induced faults caused by microelectronic hardware failure;
g) Latent, user, input/output, range, and other faults that are only detectable when a given state occurs; and
h) Failure of the programmable component to perform any function at all.
Product standard requirements may amend or supersede the requirements in this standard, as appropriate.
URI: http://yse.yabesh.ir/std/handle/yse/221933
Collections :
  • UL - UL
  • Download PDF : (18.58Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UL 1998 BULLETIN

Show full item record

contributor authorUL - UL
date accessioned2017-09-04T18:40:20Z
date available2017-09-04T18:40:20Z
date copyright04/19/2011
date issued2011
identifier otherJUJBIEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/221933
description abstractThese requirements apply to non-networked embedded microprocessor software whose failure is capable of resulting in a risk of fire, electric shock, or injury to persons.
This is a reference standard in which the requirements are to be applied when specifically referenced by other standards or product safety requirements.
These requirements address the risks unique to product hardware controlled by software in programmable components.
These requirements are intended to supplement applicable product or component standards and requirements, and are not intended to serve as the sole basis for investigating the risk of fire, electric shock, or injury to persons.
These requirements are intended to address risks that occur in the software or in the process used to develop and maintain the software, such as the following:
a) Requirements conversion faults that cause differences between the specification for the programmable component and the software design;
b) Design faults such as incorrect software algorithms or interfaces;
c) Coding faults, including syntax, incorrect signs, endless loops, and other coding faults;
d) Timing faults that cause program execution to occur prematurely or late;
e) Microelectronic memory faults, such as memory failure, not enough memory, or memory overlap;
f) Induced faults caused by microelectronic hardware failure;
g) Latent, user, input/output, range, and other faults that are only detectable when a given state occurs; and
h) Failure of the programmable component to perform any function at all.
Product standard requirements may amend or supersede the requirements in this standard, as appropriate.
languageEnglish
titleUL 1998 BULLETINnum
titleUL Standard for Safety Software in Programmable Components - COMMENTS DUE: May 19, 2011en
typestandard
page2
statusRevised
treeUL - UL:;2011
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian