Show simple item record

UL Standard for Safety Machine-Tool Wires and Cables - COMMENTS DUE: February 6, 2012

contributor authorUL - UL
date accessioned2017-09-04T18:46:34Z
date available2017-09-04T18:46:34Z
date copyright01/06/2012
date issued2012
identifier otherKJWQTEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/227831
description abstractThese requirements cover all-thermoplastic Type MTW, 600-V, machine-tool wires and cables for use as specified in the National Electrical Code (ANSI/NFPA 70), and in the National Fire Protection Association Electrical Standard for Industrial Machinery (ANSI/NFPA 79). These wires and cables comply with a flame test and are for use at 90°C (194°F) and lower temperatures in dry locations and at 60°C (140°F) and lower temperatures where exposed to moisture, oil, or coolants such as cutting oils and the like.
The two single-conductor constructions covered are described in Table 1.1. Both are PVC-insulated and one includes a nylon jacket over the insulation. The multiple-conductor constructions covered consist of assemblies of these single-conductor constructions (sizes and styles may be mixed) enclosed by a PVC jacket.
languageEnglish
titleUL 1063 BULLETINnum
titleUL Standard for Safety Machine-Tool Wires and Cables - COMMENTS DUE: February 6, 2012en
typestandard
page2
statusActive
treeUL - UL:;2012
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record