UL 1063 BULLETIN
UL Standard for Safety Machine-Tool Wires and Cables - COMMENTS DUE: February 6, 2012
Organization:
UL - UL
Year: 2012
Abstract: These requirements cover all-thermoplastic Type MTW, 600-V, machine-tool wires and cables for use as specified in the National Electrical Code (ANSI/NFPA 70), and in the National Fire Protection Association Electrical Standard for Industrial Machinery (ANSI/NFPA 79). These wires and cables comply with a flame test and are for use at 90°C (194°F) and lower temperatures in dry locations and at 60°C (140°F) and lower temperatures where exposed to moisture, oil, or coolants such as cutting oils and the like.
The two single-conductor constructions covered are described in Table 1.1. Both are PVC-insulated and one includes a nylon jacket over the insulation. The multiple-conductor constructions covered consist of assemblies of these single-conductor constructions (sizes and styles may be mixed) enclosed by a PVC jacket.
The two single-conductor constructions covered are described in Table 1.1. Both are PVC-insulated and one includes a nylon jacket over the insulation. The multiple-conductor constructions covered consist of assemblies of these single-conductor constructions (sizes and styles may be mixed) enclosed by a PVC jacket.
Collections
:
-
Statistics
UL 1063 BULLETIN
Show full item record
| contributor author | UL - UL | |
| date accessioned | 2017-09-04T18:46:34Z | |
| date available | 2017-09-04T18:46:34Z | |
| date copyright | 01/06/2012 | |
| date issued | 2012 | |
| identifier other | KJWQTEAAAAAAAAAA.pdf | |
| identifier uri | http://yse.yabesh.ir/std/handle/yse/227831 | |
| description abstract | These requirements cover all-thermoplastic Type MTW, 600-V, machine-tool wires and cables for use as specified in the National Electrical Code (ANSI/NFPA 70), and in the National Fire Protection Association Electrical Standard for Industrial Machinery (ANSI/NFPA 79). These wires and cables comply with a flame test and are for use at 90°C (194°F) and lower temperatures in dry locations and at 60°C (140°F) and lower temperatures where exposed to moisture, oil, or coolants such as cutting oils and the like. The two single-conductor constructions covered are described in Table 1.1. Both are PVC-insulated and one includes a nylon jacket over the insulation. The multiple-conductor constructions covered consist of assemblies of these single-conductor constructions (sizes and styles may be mixed) enclosed by a PVC jacket. | |
| language | English | |
| title | UL 1063 BULLETIN | num |
| title | UL Standard for Safety Machine-Tool Wires and Cables - COMMENTS DUE: February 6, 2012 | en |
| type | standard | |
| page | 2 | |
| status | Active | |
| tree | UL - UL:;2012 | |
| contenttype | fulltext |

درباره ما