UL 443

UL Standard for Safety Steel Auxiliary Tanks for Oil-Burner Fuel - Sixth Edition; Reprint with revisions through and including March 8, 2013

Organization:
UL - UL
Year: 2006

Abstract: These requirements cover the design and construction of welded steel tanks of the atmospheric type intended for the auxiliary storage and supply of fuel oil for oil burners. They are for use in the supply piping between a burner and its main fuel supply tank.
These tanks are intended for installation and use in accordance with the Standard of the National Fire Protection Association for the Installation of Oil-Burning Equipment, NFPA No. 31.
An auxiliary tank equipped with a mechanism for control of a pump or otherwise controlling liquid level or for preventing the spillage of fuel oil from a tank not required to be vented to the outside of a building is to be judged under the Standard for Pumps for Oil-Burning Appliances, UL 343.
A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of fire, electric shock, or injury to persons shall be evaluated using the appropriate additional component and end-product requirements as determined necessary to maintain the acceptable level of safety as originally anticipated by the intent of this standard. A product whose features, characteristics, components, materials, or systems conflict with specific requirements or provisions of this standard cannot be judged to comply with this standard. Where considered appropriate, revision of requirements shall be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this standard.
URI: http://yse.yabesh.ir/std/handle/yse/228775
Collections :
  • UL - UL
  • Download PDF : (644.6Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UL 443

Show full item record

contributor authorUL - UL
date accessioned2017-09-04T18:47:35Z
date available2017-09-04T18:47:35Z
date copyright39015
date issued2006
identifier otherKMJXBFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/228775
description abstractThese requirements cover the design and construction of welded steel tanks of the atmospheric type intended for the auxiliary storage and supply of fuel oil for oil burners. They are for use in the supply piping between a burner and its main fuel supply tank.
These tanks are intended for installation and use in accordance with the Standard of the National Fire Protection Association for the Installation of Oil-Burning Equipment, NFPA No. 31.
An auxiliary tank equipped with a mechanism for control of a pump or otherwise controlling liquid level or for preventing the spillage of fuel oil from a tank not required to be vented to the outside of a building is to be judged under the Standard for Pumps for Oil-Burning Appliances, UL 343.
A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of fire, electric shock, or injury to persons shall be evaluated using the appropriate additional component and end-product requirements as determined necessary to maintain the acceptable level of safety as originally anticipated by the intent of this standard. A product whose features, characteristics, components, materials, or systems conflict with specific requirements or provisions of this standard cannot be judged to comply with this standard. Where considered appropriate, revision of requirements shall be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this standard.
languageEnglish
titleUL 443num
titleUL Standard for Safety Steel Auxiliary Tanks for Oil-Burner Fuel - Sixth Edition; Reprint with revisions through and including March 8, 2013en
typestandard
page20
statusActive
treeUL - UL:;2006
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian