Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon Number
D7504 - 16
Organization:
ASTM - ASTM International
Year: 2016
Abstract: Specification for Nitration Grade Toluene
Subject: aromatics
Collections
:
-
Statistics
Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon Number
Show full item record
contributor author | ASTM - ASTM International | |
date accessioned | 2017-10-28T13:19:04Z | |
date available | 2017-10-28T13:19:04Z | |
date issued | 2016 | |
identifier other | D7504-16.pdf | |
identifier uri | http://yse.yabesh.ir/std/handle/yse/244482 | |
description | D7504 - 16 Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon Number , aromatics, benzene, ECN, ethylbenzene, gas chromatography, impurities, mixed xylenes, purity, | |
description abstract | Specification for Nitration Grade Toluene | |
language | English | |
title | Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon Number | en |
title | D7504 - 16 | num |
type | standard | |
status | Historical Standard | |
tree | ASTM - ASTM International:;2016 | |
contenttype | fulltext | |
subject keywords | aromatics | |
subject keywords | benzene | |
subject keywords | ECN | |
subject keywords | ethylbenzene | |
subject keywords | gas chromatography | |
subject keywords | impurities | |
subject keywords | mixed xylenes | |
subject keywords | purity | |
subject keywords | ||
subject keywords | ||
subject keywords | styrene | |
subject keywords | toluene | |
scope | This test method covers the determination of total nonaromatic hydrocarbons and monocyclic aromatic hydrocarbons in benzene, toluene, ethylbenzene, p-xylene, o-xylene, styrene and mixed xylenes by gas chromatography. The purity of benzene, toluene, ethylbenzene, p-xylene, o-xylene, styrene and mixed xylenes is also calculated. Similar test methods, using the internal standard calibration technique and the external standard calibration technique, are Test Methods D2360, D3797, D4492, D5060, D5135, D5917, and D6563 respectively.;A small amount of benzene in toluene, ethylbenzene, p-xylene, o-xylene, styrene and mixed xylenes may not be distinguished from the non-aromatics and the concentrations are determined as a composite (see 6.1).The limit of detection (LOD) is 0.0002 wt % and limit of quantitation (LOQ) is 0.0006 wt % for impurities in toluene, mixed xylenes, p-xylene, o-xylene, ethylbenzene, benzene, and styrene.;In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |