• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • ASTM - ASTM International
  • View Item
  •   YSE
  • Industrial Standards
  • ASTM - ASTM International
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

Standard Practice for Structural Design of Corrugated Steel Pipe, Pipe-Arches, and Arches for Storm and Sanitary Sewers and Other Buried Applications

A796 - 17

Organization:
ASTM - ASTM International
Year: 2017

Abstract: This specification covers corrugated steel pipe and pipe-arches, ribbed and composite ribbed steel pipe, ribbed pipe with metallic-coated inserts, closed rib steel pipe, composite corrugated steel pipe, and steel structural plate pipe, pipe-arches, and underpasses for use as storm sewers and sanitary sewers, and other buried applications. The design load or pressure on a pipe is comprised of earth load, live load, and impact load. These loads are applied as fluid pressure acting on the pipe periphery. Strength requirements for wall strength, buckling strength, and seam strength may be determined by either the allowable stress design method or by the load and resistance design method. The thrust in the pipe wall shall be checked by three criteria. Each considers the joint function of the steel pipe and the surrounding soil envelope. The pipe design using the LRFD method is presented. The pipe shall have enough rigidity to withstand the forces that are normally applied during shipment, handling, and installation. Where pipe is to be placed under roads, streets, or freeways, the minimum cover requirements shall be determined. Corrugated steel pipe composed of a smooth interior steel liner and a corrugated steel exterior shell that are attached integrally at the continuous helical lock seam shall be designed as specified. Smooth pipe with ribs shall be designed on the same basis as a standard corrugated steel pipe. Composite corrugated steel pipe of all types shall be designed on the same basis as standard corrugated steel pipe with a curve and tangent profile. Pipe-arch and underpass design shall be similar to round pipe using twice the top radius as the span. The performance of a flexible corrugated steel pipe is dependent on soil-structure interaction and soil stiffness. The construction and installation of corrugated steel pipe and pipe-arches and steel structural plate pipe, pipe-arches, arches, and underpasses shall conform accordingly.
URI: http://yse.yabesh.ir/std/handle/yse/248650
Subject: abrasive conditions
Collections :
  • ASTM - ASTM International
  • Download PDF : (627.2Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Standard Practice for Structural Design of Corrugated Steel Pipe, Pipe-Arches, and Arches for Storm and Sanitary Sewers and Other Buried Applications

Show full item record

contributor authorASTM - ASTM International
date accessioned2017-10-28T13:35:25Z
date available2017-10-28T13:35:25Z
date issued2017
identifier otherA796A796M.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/248650
descriptionA796 - 17 Standard Practice for Structural Design of Corrugated Steel Pipe, Pipe-Arches, and Arches for Storm and Sanitary Sewers and Other Buried Applications , abrasive conditions, buried applications, composite structure, corrosive conditions, corrugated steel pipe, dead loads, embankment installation, handling and installation, live loads, minimum cover, sectional properties, sewers, steel pipe structural design, trench installation,,
description abstractThis specification covers corrugated steel pipe and pipe-arches, ribbed and composite ribbed steel pipe, ribbed pipe with metallic-coated inserts, closed rib steel pipe, composite corrugated steel pipe, and steel structural plate pipe, pipe-arches, and underpasses for use as storm sewers and sanitary sewers, and other buried applications. The design load or pressure on a pipe is comprised of earth load, live load, and impact load. These loads are applied as fluid pressure acting on the pipe periphery. Strength requirements for wall strength, buckling strength, and seam strength may be determined by either the allowable stress design method or by the load and resistance design method. The thrust in the pipe wall shall be checked by three criteria. Each considers the joint function of the steel pipe and the surrounding soil envelope. The pipe design using the LRFD method is presented. The pipe shall have enough rigidity to withstand the forces that are normally applied during shipment, handling, and installation. Where pipe is to be placed under roads, streets, or freeways, the minimum cover requirements shall be determined. Corrugated steel pipe composed of a smooth interior steel liner and a corrugated steel exterior shell that are attached integrally at the continuous helical lock seam shall be designed as specified. Smooth pipe with ribs shall be designed on the same basis as a standard corrugated steel pipe. Composite corrugated steel pipe of all types shall be designed on the same basis as standard corrugated steel pipe with a curve and tangent profile. Pipe-arch and underpass design shall be similar to round pipe using twice the top radius as the span. The performance of a flexible corrugated steel pipe is dependent on soil-structure interaction and soil stiffness. The construction and installation of corrugated steel pipe and pipe-arches and steel structural plate pipe, pipe-arches, arches, and underpasses shall conform accordingly.
languageEnglish
titleStandard Practice for Structural Design of Corrugated Steel Pipe, Pipe-Arches, and Arches for Storm and Sanitary Sewers and Other Buried Applicationsen
titleA796 - 17num
typestandard
statusActive Standard
treeASTM - ASTM International:;2017
contenttypefulltext
subject keywordsabrasive conditions
subject keywordsburied applications
subject keywordscomposite structure
subject keywordscorrosive conditions
subject keywordscorrugated steel pipe
subject keywordsdead loads
subject keywordsembankment installation
subject keywordshandling and installation
subject keywordslive loads
subject keywordsminimum cover
subject keywordssectional properties
subject keywordssewers
subject keywordssteel pipe structural design
subject keywordstrench installation
scopeThis practice covers the structural design of corrugated steel pipe and pipe-arches, ribbed and composite ribbed steel pipe, ribbed pipe with metallic-coated inserts, closed rib steel pipe, composite corrugated steel pipe, and steel structural plate pipe, pipe-arches, and underpasses for use as storm sewers and sanitary sewers, and other buried applications. Ribbed and composite ribbed steel pipe, ribbed pipe with metallic-coated inserts, closed rib steel pipe, and composite corrugated steel pipe shall be of helical fabrication having a continuous lockseam. This practice is for pipe installed in a trench or embankment and subjected to earth loads and live loads. It must be recognized that a buried corrugated steel pipe is a composite structure made up of the steel ring and the soil envelope, and both elements play a vital part in the structural design of this type of structure. This practice applies to structures installed in accordance with Practice A798/A798M or A807/A807M.;Corrugated steel pipe and pipe-arches shall be of annular fabrication using riveted or spot-welded seams, or of helical fabrication having a continuous lockseam or welded seam.Structural plate pipe, pipe-arches, underpasses, and arches are fabricated in separate plates that, when assembled at the job site by bolting, form the required shape.;Deep corrugated plates are covered in this standard as a means of providing design properties only. The structural design of deep corrugated structures is not supported by this standard.

1.5 This specification is applicable to design in inch-pound units as A796 or in SI units as A796M. Inch-pound units and SI units are not necessarily equivalent. SI units are shown in brackets in the text for clarity, but they are the applicable values when the design is done per A796M.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian