Manual of Petroleum MeasurementStandards Chapter 11.2.4Temperature Correction for theVolume of NGL and LPG Tables 23E,24E, 53E, 54E, 59E, and 60E -SECOND EDITION
API MPMS 11.2.4
Organization:
API - American Petroleum Institute
Year: 2019
Abstract: The actual standard represented by this report consists of the explicit implementation procedures.
Sample tables, flow charts, and specific examples created from a computerized version of these implementation procedures are presented within.
The examples are to provide guides and check points to those who wish to implement a computerized procedure to represent the Standard, however these are not a part of the actual Standard.
This standard covers a 60 °F relative density range of 0.3500 to 0.6880 which nominally equates to a density at 15 °C of 351.7 kg/m3 to 687.8 kg/m3 and a density at 20 °C of 331.7 kg/m3 to 683.6 kg/m3.
The temperature range of this standard is –50.8 °F to 199.4 °F (–46 °C to 93 °C).
At all conditions, the pressure is assumed to be at saturation conditions (also known as bubble point or saturation vapor pressure).
Collections
:
-
Statistics
Manual of Petroleum MeasurementStandards Chapter 11.2.4Temperature Correction for theVolume of NGL and LPG Tables 23E,24E, 53E, 54E, 59E, and 60E -SECOND EDITION
Show full item record
contributor author | API - American Petroleum Institute | |
date accessioned | 2020-07-05T04:36:10Z | |
date available | 2020-07-05T04:36:10Z | |
date copyright | June 2019 | |
date issued | 2019 | |
identifier other | WRZYHGAAAAAAAAAA.pdf | |
identifier uri | http://yse.yabesh.ir/std/handle/yse/279851 | |
description abstract | The actual standard represented by this report consists of the explicit implementation procedures. Sample tables, flow charts, and specific examples created from a computerized version of these implementation procedures are presented within. The examples are to provide guides and check points to those who wish to implement a computerized procedure to represent the Standard, however these are not a part of the actual Standard. This standard covers a 60 °F relative density range of 0.3500 to 0.6880 which nominally equates to a density at 15 °C of 351.7 kg/m3 to 687.8 kg/m3 and a density at 20 °C of 331.7 kg/m3 to 683.6 kg/m3. The temperature range of this standard is –50.8 °F to 199.4 °F (–46 °C to 93 °C). At all conditions, the pressure is assumed to be at saturation conditions (also known as bubble point or saturation vapor pressure). | |
language | English | |
title | Manual of Petroleum MeasurementStandards Chapter 11.2.4Temperature Correction for theVolume of NGL and LPG Tables 23E,24E, 53E, 54E, 59E, and 60E -SECOND EDITION | en |
title | API MPMS 11.2.4 | num |
type | standard | |
page | 155 | |
status | Active | |
tree | API - American Petroleum Institute:;2019 | |
contenttype | fulltext |