NACE 1D199

Internal Corrosion Monitoring of Subsea Production and Injection Systems - Item No. 24202

Organization:
NACE - NACE International
Year: 1999

Abstract: General
Corrosion monitoring techniques can be divided into intrusive and nonintrusive methods. Intrusive methods are those that access the inside of a system. Nonintrusive systems do not require internal access. This distinction is particularly critical in subsea use because of the difficulty in using intrusive devices in underwater locations, especially at greater depths.
Nonintrusive monitoring systems include the field signature method, thin layer activation, and fixed ultrasonic testing (UT). These systems and others are the focus of this technical committee report.
URI: http://yse.yabesh.ir/std/handle/yse/39573
Collections :
  • NACE - NACE International
  • Download PDF : (133.4Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NACE 1D199

Show full item record

contributor authorNACE - NACE International
date accessioned2017-09-04T15:37:40Z
date available2017-09-04T15:37:40Z
date copyright1999.06.01
date issued1999
identifier otherOVREACAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/39573
description abstractGeneral
Corrosion monitoring techniques can be divided into intrusive and nonintrusive methods. Intrusive methods are those that access the inside of a system. Nonintrusive systems do not require internal access. This distinction is particularly critical in subsea use because of the difficulty in using intrusive devices in underwater locations, especially at greater depths.
Nonintrusive monitoring systems include the field signature method, thin layer activation, and fixed ultrasonic testing (UT). These systems and others are the focus of this technical committee report.
languageEnglish
titleNACE 1D199num
titleInternal Corrosion Monitoring of Subsea Production and Injection Systems - Item No. 24202en
typestandard
page13
statusActive
treeNACE - NACE International:;1999
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian