TIA TIA-455-186
FOTP-186 Gauge Retention Force Measurement for Fiber Optic Components - ANSI APPROVAL WITHDRAWN MARCH, 2004
Organization:
TIA - Telecommunications Industry Association
Year: 1991
Abstract: INTRODUCTION
Intent
This procedure is used to measure the retention characteristics of the resilient member of a fiber optic component (most commonly a connector). It is specifically intended for use when it is impracticable to define acceptance/rejection criteria for resilient members by the use of size dimensions.
Description
The method is applicable to either male or female resilient members. For the case of a male member, a ring gauge is forced over the member and the minimum frictional force to pull it off is assessed by its ability to pick up a weight. The procedure is identical for a female resilient member except that a gauge pin is substituted for the ring gauge.
Alternative Procedures
This test procedure is an alternative to the measurement procedure, titled Gauge Retention Force, of IEC 874-1, Third Edition.
Intent
This procedure is used to measure the retention characteristics of the resilient member of a fiber optic component (most commonly a connector). It is specifically intended for use when it is impracticable to define acceptance/rejection criteria for resilient members by the use of size dimensions.
Description
The method is applicable to either male or female resilient members. For the case of a male member, a ring gauge is forced over the member and the minimum frictional force to pull it off is assessed by its ability to pick up a weight. The procedure is identical for a female resilient member except that a gauge pin is substituted for the ring gauge.
Alternative Procedures
This test procedure is an alternative to the measurement procedure, titled Gauge Retention Force, of IEC 874-1, Third Edition.
Collections
:
-
Statistics
TIA TIA-455-186
Show full item record
contributor author | TIA - Telecommunications Industry Association | |
date accessioned | 2017-09-04T15:32:12Z | |
date available | 2017-09-04T15:32:12Z | |
date copyright | 07/01/1991 | |
date issued | 1991 | |
identifier other | OGBCJAAAAAAAAAAA.pdf | |
identifier uri | http://yse.yabesh.ir/std;jsessionid=A33FFBB4A04818B251172099FA6814F7/handle/yse/33813 | |
description abstract | INTRODUCTION Intent This procedure is used to measure the retention characteristics of the resilient member of a fiber optic component (most commonly a connector). It is specifically intended for use when it is impracticable to define acceptance/rejection criteria for resilient members by the use of size dimensions. Description The method is applicable to either male or female resilient members. For the case of a male member, a ring gauge is forced over the member and the minimum frictional force to pull it off is assessed by its ability to pick up a weight. The procedure is identical for a female resilient member except that a gauge pin is substituted for the ring gauge. Alternative Procedures This test procedure is an alternative to the measurement procedure, titled Gauge Retention Force, of IEC 874-1, Third Edition. | |
language | English | |
title | TIA TIA-455-186 | num |
title | FOTP-186 Gauge Retention Force Measurement for Fiber Optic Components - ANSI APPROVAL WITHDRAWN MARCH, 2004 | en |
type | standard | |
page | 12 | |
status | Active | |
tree | TIA - Telecommunications Industry Association:;1991 | |