ECA 214

Calculation of Current Ratings on Hookup Wire, Method fo

Organization:
ECIA - Electronic Components Industry Association
Year: 1981

Abstract: The method of calculation provided by this recommended practice applies to the following conditions :
Continuous currents and thermal equilibrium. Current may be either direct. or alternating. Alternating current may be single or multiphase, at frequencies up to 800 cycles per second: above 800 cycles, the AC resistance must be corrected for skin and proximity effects.
Insulated wires in air subject to convection and radiation. Heat transfer from the wires to the surroundings by conduction is negligible. Specific environmental conditions such as altitude, ambient air temperature, type of convection, etc,, must be fixed for each calculation.
Wire construction.
Conductors of circular cross-section ; fabricated of any metal, solid or stranded. If stranded, the conductor should form a compact circular unit.
Close-fitting insulation, concentric with the conductor, consisting of one or more layers of different materials.
URI: http://yse.yabesh.ir/std;query=autho470393FD081D20686159DD6EFDEC9FCD0Facilities%20Engineering%20Command%226EFDEC9FCD/handle/yse/163041
Collections :
  • ECIA - Electronic Components Industry Association
  • Download PDF : (756.6Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ECA 214

Show full item record

contributor authorECIA - Electronic Components Industry Association
date accessioned2017-09-04T17:40:01Z
date available2017-09-04T17:40:01Z
date copyright01/01/1958 (R 1981)
date issued1981
identifier otherDUFZCAAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho470393FD081D20686159DD6EFDEC9FCD0Facilities%20Engineering%20Command%226EFDEC9FCD/handle/yse/163041
description abstractThe method of calculation provided by this recommended practice applies to the following conditions :
Continuous currents and thermal equilibrium. Current may be either direct. or alternating. Alternating current may be single or multiphase, at frequencies up to 800 cycles per second: above 800 cycles, the AC resistance must be corrected for skin and proximity effects.
Insulated wires in air subject to convection and radiation. Heat transfer from the wires to the surroundings by conduction is negligible. Specific environmental conditions such as altitude, ambient air temperature, type of convection, etc,, must be fixed for each calculation.
Wire construction.
Conductors of circular cross-section ; fabricated of any metal, solid or stranded. If stranded, the conductor should form a compact circular unit.
Close-fitting insulation, concentric with the conductor, consisting of one or more layers of different materials.
languageEnglish
titleECA 214num
titleCalculation of Current Ratings on Hookup Wire, Method foen
typestandard
page8
statusActive
treeECIA - Electronic Components Industry Association:;1981
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian