IEEE Trial-Use Standard for Testing and Evaluating the Dielectric Performance of Celebratory Balloons in Contact with Overhead Power Distribution Lines Rated up to 38 kV System Voltage
IEEE Std 2845-2023
Year: 2023
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Abstract: This standard is applicable to celebratory balloons that are comparable in size and shape to what are commonly referred to as foil balloons and are available in retail stores and filled with helium or a lighter-than-air gas. The dielectric performance of celebratory balloons in contact with simulated energized overhead distribution power lines with the intent of minimizing balloon-caused power system outages (or electrical faults) are evaluated by the test procedures. The scope is limited to distribution system voltages of 38 kV or less and only single balloons. The effects of having any moisture, contaminants, or string or ribbon attachments to the balloon(s) are not investigated under this procedure. An errata can be found at: https://standards.ieee.org/wp-content/uploads/2024/05/2845-2023_errata.pdf.
Subject: balloon
-
Statistics
IEEE Trial-Use Standard for Testing and Evaluating the Dielectric Performance of Celebratory Balloons in Contact with Overhead Power Distribution Lines Rated up to 38 kV System Voltage
Show full item record
contributor author | IEEE - The Institute of Electrical and Electronics Engineers, Inc. | |
date accessioned | 2024-12-17T08:08:51Z | |
date available | 2024-12-17T08:08:51Z | |
date copyright | 01 December 2023 | |
date issued | 2023 | |
identifier other | 10342654.pdf | |
identifier uri | http://yse.yabesh.ir/std;query=author:%22NAVY%20-%20YD%20-%20Naval%20Facilities%20Engineering%20Command%22/handle/yse/336292 | |
description abstract | This standard is applicable to celebratory balloons that are comparable in size and shape to what are commonly referred to as foil balloons and are available in retail stores and filled with helium or a lighter-than-air gas. The dielectric performance of celebratory balloons in contact with simulated energized overhead distribution power lines with the intent of minimizing balloon-caused power system outages (or electrical faults) are evaluated by the test procedures. The scope is limited to distribution system voltages of 38 kV or less and only single balloons. The effects of having any moisture, contaminants, or string or ribbon attachments to the balloon(s) are not investigated under this procedure. An errata can be found at: https://standards.ieee.org/wp-content/uploads/2024/05/2845-2023_errata.pdf. | |
language | English | |
publisher | IEEE - The Institute of Electrical and Electronics Engineers, Inc. | |
title | IEEE Trial-Use Standard for Testing and Evaluating the Dielectric Performance of Celebratory Balloons in Contact with Overhead Power Distribution Lines Rated up to 38 kV System Voltage | en |
title | IEEE Std 2845-2023 | num |
type | standard | |
page | 51 | |
status | Active | |
tree | IEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2023 | |
contenttype | fulltext | |
subject keywords | balloon | |
subject keywords | IEEE 2845™ | |
subject keywords | nonconductive balloon | |
subject keywords | foil balloon | |
subject keywords | ionization | |
subject keywords | standard | |
subject keywords | ignition | |
identifier DOI | 10.1109/IEEESTD.2023.10342654 |