IEEE - The Institute of Electrical and Electronics Engineers, Inc.: Recent submissions
Now showing items 1221-1240 of 2832
-
IEEE Guide for Incorporating Human Reliability Analysis into Probabilistic Risk Assessments for Nuclear Power Generating Stations and Other Nuclear Facilities
Abstract: A structured framework for the incorporation of human reliability analysis (HRA) into probabilistic risk assessments (PRAs) is provided in this guide. To enhance the analysis of human/system interactions in PRAs, to help ...Subject(s) : HRA , IEEE 1082(TM) , PRA , human reliability analysis , probabilistic risk assessment , IEEE Standards , Nuclear power generation , Power system reliability , Probability distribution , Risk management , -
American National Standard Instrumentation and Systems for Monitoring Airborne Radioactivity
Abstract: The complexity associated with quantitative assay and monitoring of aerosols and gasses can be substantial. This standard covers system design, manufacture, performance, testing, calibration, and maintenance requirements ...Subject(s) : ANSI 42.54 , aerosol , air monitoring , noble gas , radioiodine , transuranic , tritium , ANSI Standards , Airborne radar , Monitoring , Radiation detectors , Radiation monitoring , Radioactive pollution , -
IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces
Abstract: The technical specifications for, and testing of, the interconnection and interoperability between utility electric power systems (EPSs) and distributed energy resources (DERs) are the focus of this standard. It provides ...Subject(s) : IEEE 1547(TM) , certification , clearing time , codes , commissioning , communications , dc injection , design , diesel generators , dispersed generation , distributed generation , electric distribution systems , electric power systems , energy resources , energy storage , faults , field , flicker , frequency support , fuel cells , generators , grid , grid support , harmonics , induction machines , installation , interconnection requirements and specifications , interoperability , inverters , islanding , microturbines , monitoring and control , networks , paralleling , performance , photovoltaic power systems , point of common coupling , power , power converters , production tests , protection functions , public utility commissions , quality , reclosing coordination , regulations , ride through , rule-making , standards , storage , synchronous machines , testing , trip setting , utilities , voltage regulation , wind energy systems , Diesel engines , Energy management , Energy storage , Fault diagnosis , Flicker , Generators , IEEE Standards , Power distribution , Power systems reliability , -
IEEE Standard for Automatic Test Markup Language (ATML) Unit Under Test (UUT) Description
Abstract: An exchange format utilizing Extensible Markup Language (XML) for both the static description of unit under test (UUT) and the specific description of UUT instance information is defined in this standard.Subject(s) : ATML Instance Document , Automatic Test Markup Language (ATML) , IEEE 1671.3(TM) , XML schema , automatic test equipment (ATE) , automatic test system (ATS) , unit under test (UUT) , IEEE Standards , Markup languages , Testing , XML , -
IEEE Standard for the Measurement of Audible Noise from Overhead Transmission Lines
Abstract: Uniform procedures are established for manual and automatic measurement of audible noise from overhead transmission lines. Their purpose is to allow valid evaluation and comparison of the audible noise performance of various ...Subject(s) : IEEE 656(TM) , audible noise , overhead transmission lines , IEEE Standards , Noise measurement , Power transmission lines , -
IEEE Standard for Definitions of High-Voltage Circuit Breakers Above 1000 Vac and 3200 Vdc, and Reclosers and Other Distribution Equipment from 1000 Vac to 38 000 Vac
Abstract: The terms and definitions in the standard are intended to encompass the products within the scope of the IEEE C37 series of power switchgear standards for high-voltage circuit breakers (above 1000 Vac and 3200 Vdc) and for ...Subject(s) : IEEE C37.100.5(TM) , capacitor switch , circuit breaker , definitions , fault interrupter , padmounted switchgear , recloser , sectionalizer , submersible switchgear , switchgear , Capacitors , Circuit breakers , Fault protection , High-voltage techniques , IEEE Standards , Switchgear , IEEE standards , circuit breakers , IEEE C37 series , IEEE standard , distribution equipment , high-voltage circuit breakers , power switchgear standards , reclosers , -
ISO/IEC/IEEE International Standard for Ethernet Amendment 7: Media Access Control Parameters, Physical Layers, and Management Parameters for 2.5 Gb/s and 5 Gb/s Operation, Types 2.5GBASE-T and 5GBASE-T
Abstract: Protocols, procedures, and managed objects to allow IEEE 802.11 media to provide internal connections within bridged networks, as well as access to bridged networks, are provided in this amendment.Subject(s) : IEEE 802.11(TM) , IEEE 802.1Q(TM) , LANs , MAC Bridges , VLANs , Wi-Fi , amendment , local area networks , transparent bridging , wireless , Bridge circuits , IEC Standards , IEEE Standards , ISO Standards , Local area networks , Media Access Protocol , Metropolitan area networks , Wireless LAN , Wireless fidelity , -
ISO/IEC/IEEE Information technology--Telecommunications and information exchange between systems--Local and metropolitan area networks--Specific requirements -- Part 1Q: Bridges and bridged networks AMENDMENT 2: Application virtual local area network (VLA
Abstract: Enhancements to the set of TLVs used by the Data Center Bridging eXchange protocol (DCBX) for the purpose of simplifying the management of networks utilizing Data Center Bridging (DCB) features are defined in this amendment ...Subject(s) : Bridged Networks , Data Center Bridging (DCB) , Data Center Bridging eXchange protocol (DCBX) , IEEE 802(R) , IEEE 802.1Q(TM) , IEEE 802.1Qcd(TM) , MAC Bridges , VLAN Bridges , Virtual Bridged Networks (virtual LANs) , local area networks (LANs) , metropolitan area networks , Bridge circuits , Data centers , IEC Standards , IEEE Standards , ISO Standards , Information exchange , Local area networks , Media Access Protocol , Metropolitan area networks , Virtual LAN , -
IEEE Standard for Qualification of Class 1E Vented Lead Acid Storage Batteries for Nuclear Power Generating Stations - Corrigenda 1
Abstract: This corrigenda clarifies the accelerated aging process for duty cycles greater than 8 h.Subject(s) : IEEE 450 , IEEE 535 , acceptance test , performance test , vented lead-acid battery , Batteries , IEEE Standards , Lead acid batteries , Lead compounds , Nuclear power generation , Performance evaluation , Safety , Ventilation , IEEE standards , ageing , lead acid batteries , nuclear power stations , IEEE standard , accelerated aging process , class 1E vented lead acid storage batteries qualification , duty cycles , nuclear power generating stations , -
ISO/IEEE International Standard - Health informatics -- Point-of-care medical device communication -- Part 10101: Nomenclature AMENDMENT 1: Additional definitions
Abstract: Within the context of the ISO/IEEE 11073 family of standards for point-of-care (POC) medical device communication (MDC), the nomenclature defined by the base ISO/IEEE 11073-10101:2004 nomenclature standard is extended by ...Subject(s) : Continua , IEEE 11073-10101a , IHE PCD , ISO/IEEE 11073-10101 , NTP , PCHA , POC , Personal Connected Health Alliance , alert communication , anesthesia , blood gas , codes , fluid-related metrics , haemodynamics , information model , measurement sites , medical device certification , medical device communication , neurology , nomenclature , ontology , patient , point-of-care , respiration , semantics , service model , terminology , time synchronization , timekeeping , units of measure , urine , ventilation , Bioinformatics , Health information management , IEEE Standards , ISO Standards , Patient monitoring , Point of care , -
ISO/IEC/IEEE International Standard - Information technology -- Telecommunications and information exchange between systems -- Local and metropolitan area networks -- Specific requirements -- Part 15-6: Wireless body area network
Abstract: Short-range, wireless communications in the vicinity of, or inside, a human body (but not limited to humans) are specified in this standard. It uses existing industrial scientific medical (ISM) bands as well as frequency ...Subject(s) : BAN , IEEE 802.15.6 , body area network , Body area networks , IEC Standards , IEEE Standards , ISO Standards , Information exchange , Information technology , Local area networks , Metropolitan area networks , -
ISO/IEC/IEEE International Standard-Information technology--Telecommunications and information exchange between systems--Local and metropolitan area networks -- Specific requirements -- Part 1Q: Bridges and bridged networks TECHNICAL CORRIGENDUM 1: Techni
Abstract: Correction of technical and editorial errors identified by the IEEE 802.1 maintenance activity are presented in this document.Subject(s) : Bridged Local Area Networks , ECMP , Equal Cost Multiple Paths , IEEE 802.1Q(TM) , LANs , MAC Bridges , MANs , Shortest Path Bridging , Virtual Bridged Local Area Networks , corrigendum , local area networks , metropolitan area networks , Bridge circuits , IEEE Standards , Local area networks , Metropolitan area networks , Path planning , Shortest path problem , -
ISO/IEC/IEEE International Standard - Amendment 5: Specification and Management Parameters for Interspersing Express Traffic
Abstract: This amendment to IEEE Std 802.3-2015 specifies additions to and appropriate modifications to add support for interspersing express traffic over a single physical link.Subject(s) : Ethernet , IEEE 802(R) , IEEE 802.3(TM) , IEEE 802.3br(TM) , express traffic , preemption , Ethernet , IEC Standards , IEEE Standards , ISO Standards , Telecommunication traffic , -
ISO/IEC/IEEE International Standard - Information technology -- Telecommunications and information exchange between systems -- Local and metropolitan area networks -- Specific requirements -- Part 15-3: High data rate wireless multi-media networks
Abstract: The protocol and compatible interconnection of data and multimedia communication equipment via 2.4 GHz and 60 GHz radio transmissions in a Wireless Personal Area Network (WPAN) using low power and multiple modulation formats ...Subject(s) : IEEE 802.15.3(TM) , ad hoc network , mm-wave , mobility , radio frequency , wireless , Ad hoc networks , IEC Standards , IEEE Standards , ISO Standards , Millimeter wave technology , Radio frequency , Wireless communication , -
IEEE Standard for Automatic Test Markup Language (ATML) Test Descriptions
Abstract: An exchange format, utilizing Extensible Markup Language (XML), for both the static description of unit under test (UUT), and the specific description of UUT instance information is defined in this standard.Subject(s) : ATE , ATML , ATML instance document , ATS , Automatic Test Markup Language , IEEE 1671.1(TM) , UUT , XML schema , automatic test equipment , automatic test system , test program documentation , test requirements , unit under test , Automatic test equipment , IEEE Standards , XML , -
IEEE Guide for the Application of Shunt Reactor Switching
Abstract: Guidance for the application of ac high-voltage circuit breakers for shunt reactor switching is provided. Overvoltage generation for the three cases of shunt reactors being directly grounded, ungrounded, or grounded through ...Subject(s) : IEEE C37.015(TM) , ac high voltage circuit breakers , application , inductive load switching , overvoltages , reignition , shunt reactor switching , small inductive currents , AC machines , Circuit breakers , High-voltage techniques , IEEE Standards , Inductors , Load management , Shunts (electrical) , -
ISO/IEC/IEEE International Standard - Information technology -- Telecommunications and information exchange between systems -- Local and metropolitan area networks -- Specific requirements -- Part 22: Cognitive Wireless RAN Medium Access Control (MAC) and
Abstract: Alternate physical layer (PHY) and necessary medium access control layer (MAC) enhancements to IEEE Std 802.22-2011 are specified in this amendment for operation in very high frequency/ultra-high frequency (VHF/UHF) ...Subject(s) : IEEE 802.22(TM) , IEEE 802.22b(TM) , WRAN standard , broadband wireless access network , enhanced broadband services , high capacity , high throughput , monitoring applications , Broadband , IEEE Standards , Information exchange , Information technology , Media Access Protocol , Throughput , Wireless sensor networks , -
ISO/IEC/IEEE International Standard-Information technology--Telecommunications and information exchange between systems--Local and metropolitan area networks--Specific requirements--Part 22: Cognitive Wireless RAN Medium Access Control (MAC) and Physical
Abstract: This air interface, including the medium access control layer (MAC) and physical layer (PHY), of the fixed and portable point-to-multipoint wireless regional area networks (WRANs) operating in spectrum allocated to the ...Subject(s) : IEEE 802.22a(TM) , WRAN standards , broadband wireless access network , cognitive radio , fixed user terminals , portable user terminals , radio spectrum sensing , regional area network , Broadcasting , Communication channels , Frequency control , IEC Standards , IEEE Standards , ISO Standards , Media Access Protocol , Physical Layer , Radio spectrum management , TV , WRAN , -
IEEE Recommended Practice for Determining the Impact of Preventative Maintenance on the Reliability of Industrial and Commercial Power Systems
Abstract: This recommended practice describes how to determine the impact of preventive maintenance on the reliability of industrial and commercial power systems. It is likely to be of greatest value to the power-oriented engineer ...Subject(s) : IEEE 3006.3(TM) , availability , failure mode , mean time between failures , reliability , Failure analysis , IEEE Standards , Maintenance engineering , Reliability , IEEE standards , power system reliability , preventive maintenance , IEEE recommended practice , commercial power system reliability , industrial power system reliability , preventative maintenance , preventive maintenance , -
IEEE Health informatics--Personal health device communication - Part 10419: Device Specialization--Insulin Pump
Abstract: Within the context of the ISO/IEEE 11073 family of standards for device communication, a normative definition of communication between personal telehealth insulin pump devices and compute engines (e.g., cell phones, personal ...Subject(s) : IEEE 11073-10419(TM) , insulin pump , medical device communication , personal health devices , Bioinformatics , Diabetes , IEEE Standards , Informatics , Insulin , Medical devices , Pumps ,

درباره ما