Browsing UFC - Unified Facilities Criteria by Issue Date
Now showing items 1-20 of 255
-
UFC 4-150-07
Abstract: This military handbook, UFC 4-150-07, is a guide for the inspection, maintenance, and repair of waterfront structures and related facilities. It is a source of reference for planning, estimating, and performing technical ... -
UFC 4-151-10
Abstract: This UFC contains general criteria for the design of piling, deck, and substructure framing and bracing, and hardware and fittings for waterfront construction. Unless indicated otherwise, these criteria also apply to the ... -
UFC 3-600-02
Abstract: PURPOSE AND SCOPE.
This UFC provides requirements for inspection, test, and maintenance (ITM) of engineered fire protection features in Department of Defense (DoD) facilities. Do not deviate from these ... -
UFC 4-150-08
Abstract: SCOPE.
This UFC, 4-105-08, is a guide for the inspection and evaluation of facility berthing capability, for all facilities providing berthing for U.S. Military Ships. It is a source of reference for ... -
UFC 3-230-02
Abstract: MIL-HDBK-1164 provides general technical guidance for operating and maintaining potable water systems at fixed military installations. Since no two installations are exactly alike, this handbook is supplemental to site-specific ... -
UFC 3-260-03
Abstract: This document is for use in evaluating Army, Air Force, Navy, and Marine Corps Airfields and Heliports and is applicable to conventional-type pavements. The procedures presented include direct sampling and nondestructive ... -
UFC 3-260-02
Abstract: This document prescribes procedures for determining the thickness, material, and density requirements for airfield pavements in nonfrost and frost areas. It includes criteria for the California Bearing Ratio (CBR) procedure ... -
UFC 3-430-11
Abstract: PURPOSE AND SCOPE.
This document provides criteria for the design of heating plant instrumentation. A heating plant contains one or more boilers. The plant may be an individual plant serving a single ... -
UFC 3-250-03
Abstract: This manual prescribes materials, mix design procedures, and construction practices for flexible pavements.
PURPOSE.
This manual provides guidance for the preparation of drawings and specifications for road and ... -
UFC 4-213-10
Abstract: This section deals with the selection of an exact location and type of drydock construction. It is assumed that the general vicinity, such as a specific shipyard, has been selected, that the size of ship to be accommodated ... -
UFC 4-826-10
Abstract: PURPOSE AND SCOPE.
This UFC provides general criteria for the design of new refrigeration systems for cold storage. This document, and all references contained herein, provides guidance to the DOD. ... -
UFC 4-740-14
Abstract: SCOPE.
UFC 4-740-14 provides guidelines for evaluating and planning the site, determining programming requirements, establishing space distribution needs, determining building size, and designing all ... -
UFC 4-721-11.1 CHANGE 1
Abstract: Purpose. This document consolidates into one source the uniform criteria for the planning, design, solicitation, proposal evaluation, and construction of Unaccompanied Enlisted Personnel Housing (UEPH) Complexes and ... -
UFC 1-900-01
Abstract: PURPOSE.
The purpose of this UFC is to provide guidance for recovery and recycling of building demolition waste. It will assist DoD facilities in determining the most feasible methods to reduce the ... -
UFC 4-740-03
Abstract: SCOPE OF DOCUMENT.
This UFC provides guidelines for evaluating, planning, and designing Navy and Marine Corps Outdoor Adventure Centers (OAC), Rental Centers (RC), and Outdoor Center & Other Rentals ... -
UFC 3-270-07
Abstract: PURPOSE AND SCOPE
This document outlines the various services’ (Army, Navy, Marine Corps, Air Force) ADR concept of operations. Recent operations identified the lack of familiarity and consistency ... -
UFC 3-430-04FA
Abstract: Purpose
This manual provides guidance for the design of high temperature water (HTW) heating systems classified as operating with supply water temperature above 240 degrees F. and designed to a pressure rating of 300 ... -
UFC 3-450-02
Abstract: Purpose and scope.
This manual provides noise control data and analysis procedures for design and construction of diesel, gas, and gas turbine engine facilities at military installations in the continental ... -
UFC 3-570-06
Abstract: This handbook provides guidance for inspection and maintenance of cathodic protection (CP) systems. It should be used by field personnel to perform scheduled inspections and preventive maintenance, and to troubleshoot and ... -
UFC 3-701-03
Abstract: Introduction
To promote macro-level analysis and planning, DoD implemented a facility classification system that groups facilities with similar functions and units of measure into Facility Analysis ...

درباره ما