MIL-T-81831
TEST SET, ALTIMETER SET AN/APM-347
Organization:
NAVY - AS - Naval Air Systems Command
Year: 1971
Abstract: The equipment covered by this specification shall be for shop use and shall provide signals and measuring devices necessary for the maintenance of the AN/APN-141 (V) Electronic Altimeter Set.
The test equipment covered by this specification shall consist of the following items:
This equipment shall operate with the following associated equipment:
Intended Use: This equipment is intended to provide the test capability required for fault isolation, repair and adjustment of the AN/APN-141 (V) Altimeter, down to the module level.
The test equipment covered by this specification shall consist of the following items:
Drawing/Model No. Nomenclature Ref. Para. 1529-0008 Test Set 3.5.1 104031-3 Case 3.5.5 104031-2 Cover 3.5.5.2
This equipment shall operate with the following associated equipment:
Test Equipment Characteristics Required Oscilloscope 5 inch screen; 4 traces; sweep Tektronix 585A speed .05 usec/cm to 50 usec/cm; trigger amplitude 0.5 to 60V pk/pk; vertical sensitivity: .02 v/cm × 5 magnification; frequency response: X-axis, DC to 1Mhz/sec; input im- pedance: 1 megohm on X-axis Digital Voltmeter Range: 0-40 VDC Cubic 240 Accuracy: .01% or 1 digit Electronic Counter 10 MHz Standard Frequency Hewlett Packard HP524D Stability 1 part in 10 Signal Generator Frequency: 4000-4500 MHz Hewlett Packard 861A Power +4 DBM with a 100 db attenuator Voltmeter Electronic Ranges: 1V to 300V full scale in Hewlett Packard 410B 6 ranges AC or DC. Accuracy: ±3% of full scale on all ranges for sinusoidal AC voltages at 400 Hz and for DC voltages.
Intended Use: This equipment is intended to provide the test capability required for fault isolation, repair and adjustment of the AN/APN-141 (V) Altimeter, down to the module level.
Collections
:
Show full item record
| contributor author | NAVY - AS - Naval Air Systems Command | |
| date accessioned | 2017-09-04T17:09:13Z | |
| date available | 2017-09-04T17:09:13Z | |
| date copyright | 07/13/1971 | |
| date issued | 1971 | |
| identifier other | YMGPDAAAAAAAAAAA.pdf | |
| identifier uri | https://yse.yabesh.ir/std/handle/yse/132693 | |
| description abstract | The equipment covered by this specification shall be for shop use and shall provide signals and measuring devices necessary for the maintenance of the AN/APN-141 (V) Electronic Altimeter Set. The test equipment covered by this specification shall consist of the following items: Drawing/Model No. Nomenclature Ref. Para. 1529-0008 Test Set 3.5.1 104031-3 Case 3.5.5 104031-2 Cover 3.5.5.2 This equipment shall operate with the following associated equipment: Test Equipment Characteristics Required Oscilloscope 5 inch screen; 4 traces; sweep Tektronix 585A speed .05 usec/cm to 50 usec/cm; trigger amplitude 0.5 to 60V pk/pk; vertical sensitivity: .02 v/cm × 5 magnification; frequency response: X-axis, DC to 1Mhz/sec; input im- pedance: 1 megohm on X-axis Digital Voltmeter Range: 0-40 VDC Cubic 240 Accuracy: .01% or 1 digit Electronic Counter 10 MHz Standard Frequency Hewlett Packard HP524D Stability 1 part in 10 Signal Generator Frequency: 4000-4500 MHz Hewlett Packard 861A Power +4 DBM with a 100 db attenuator Voltmeter Electronic Ranges: 1V to 300V full scale in Hewlett Packard 410B 6 ranges AC or DC. Accuracy: ±3% of full scale on all ranges for sinusoidal AC voltages at 400 Hz and for DC voltages. Intended Use: This equipment is intended to provide the test capability required for fault isolation, repair and adjustment of the AN/APN-141 (V) Altimeter, down to the module level. | |
| language | English | |
| title | MIL-T-81831 | num |
| title | TEST SET, ALTIMETER SET AN/APM-347 | en |
| type | standard | |
| page | 15 | |
| status | Active | |
| tree | NAVY - AS - Naval Air Systems Command:;1971 | |
| contenttype | fulltext |