AASHTO M 273M

Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers with Less Than 0.6 m of Cover Subjected to Highway Loadings [Metric]

Organization:
AASHTO - American Association of State Highway and Transportation Officials
Year: 2011

Abstract: This specification covers single-cell, precast reinforced concrete box sections with less than 0.6 m of cover subjected to highway loadings and intended to be used for the construction of culverts and for the conveyance of storm water, industrial wastes, and sewage.
This metric specification is equivalent to M 273 and is compatible in technical content.
Note 1—This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends upon the proper selection of the box section, bedding, backfill, controlled manufacture in the plant, and care that the installation conforms to the construction specifications. The owner of the precast reinforced concrete box sections specified herein is cautioned that the loading conditions and the field requirements must be correlated with the box sections specified and inspection must be provided at the construction site.
Note 2—AASHTO M 259M is to be used for box sections subjected to highway loading with 0.6 m or more earth cover, or subjected to dead load only.
Note 3—If load-and-resistance factor design (LRFD) is required, then use ASTM C 1577.
URI: https://yse.yabesh.ir/std/handle/yse/134323
Subject: Concrete box—precast
Collections :
  • AASHTO - American Association of State Highway and Transportation Officials
  • Download PDF : (902.7Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    AASHTO M 273M

Show full item record

contributor authorAASHTO - American Association of State Highway and Transportation Officials
date accessioned2017-09-04T17:10:45Z
date available2017-09-04T17:10:45Z
date copyright01/01/2011
date issued2011
identifier otherYQQONEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/134323
description abstractThis specification covers single-cell, precast reinforced concrete box sections with less than 0.6 m of cover subjected to highway loadings and intended to be used for the construction of culverts and for the conveyance of storm water, industrial wastes, and sewage.
This metric specification is equivalent to M 273 and is compatible in technical content.
Note 1—This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends upon the proper selection of the box section, bedding, backfill, controlled manufacture in the plant, and care that the installation conforms to the construction specifications. The owner of the precast reinforced concrete box sections specified herein is cautioned that the loading conditions and the field requirements must be correlated with the box sections specified and inspection must be provided at the construction site.
Note 2—AASHTO M 259M is to be used for box sections subjected to highway loading with 0.6 m or more earth cover, or subjected to dead load only.
Note 3—If load-and-resistance factor design (LRFD) is required, then use ASTM C 1577.
languageEnglish
titleAASHTO M 273Mnum
titleStandard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers with Less Than 0.6 m of Cover Subjected to Highway Loadings [Metric]en
typestandard
page16
statusActive
treeAASHTO - American Association of State Highway and Transportation Officials:;2011
contenttypefulltext
subject keywordsConcrete box—precast
subject keywordsculvert
subject keywordssewer pipe
subject keywordsstorm drain