IEEE 367

Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2012

Abstract: This recommended practice provides guidance for the calculation of power station GPR and LI voltages, as well as guidance for their appropriate reduction from worst-case values for use in metallic telecommunication protection design. Information is also included for the determination of the following:
a) The fault current and the earth return current. (The probability, waveform, and duration of these currents and the impedance to remote earthing points used in these GPR and LI calculations as well as the effective X/R ratio are discussed.)
b) The zone of influence (ZOI) of the power station GPR.
c) The calculation of the inducing currents, the mutual impedance between power and metallic telecommunication facilities, and shield factors.
d) The channel time requirements for metallic telecommunication facilities where noninterruptible channels are required for protective relaying.
URI: https://yse.yabesh.ir/std/handle/yse/156533
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (15.83Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE 367

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2017-09-04T17:33:40Z
date available2017-09-04T17:33:40Z
date copyright03/29/2012
date issued2012
identifier otherDDFMVEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/156533
description abstractThis recommended practice provides guidance for the calculation of power station GPR and LI voltages, as well as guidance for their appropriate reduction from worst-case values for use in metallic telecommunication protection design. Information is also included for the determination of the following:
a) The fault current and the earth return current. (The probability, waveform, and duration of these currents and the impedance to remote earthing points used in these GPR and LI calculations as well as the effective X/R ratio are discussed.)
b) The zone of influence (ZOI) of the power station GPR.
c) The calculation of the inducing currents, the mutual impedance between power and metallic telecommunication facilities, and shield factors.
d) The channel time requirements for metallic telecommunication facilities where noninterruptible channels are required for protective relaying.
languageEnglish
titleIEEE 367num
titleRecommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Faulten
typestandard
page168
statusActive
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2012
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian