AASHTO T 277

Standard Method of Test for Electrical Indication of Concrete’s Ability to Resist Chloride Ion Penetration

Organization:
AASHTO - American Association of State Highway and Transportation Officials
Year: 2011

Abstract: This test method covers the determination of the electrical conductance of concrete to provide a rapid indication of its resistance to the penetration of chloride ions. This test method is applicable to types of concrete where correlations have been established between this test procedure and long-term chloride ponding procedures such as those described in T 259. Examples of such correlations are discussed in References (1–5).1
The values stated in SI units are to be regarded as the standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
URI: https://yse.yabesh.ir/std/handle/yse/178524
Collections :
  • AASHTO - American Association of State Highway and Transportation Officials
  • Download PDF : (2.704Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    AASHTO T 277

Show full item record

contributor authorAASHTO - American Association of State Highway and Transportation Officials
date accessioned2017-09-04T17:55:23Z
date available2017-09-04T17:55:23Z
date copyright01/01/2007 (R 2011)
date issued2011
identifier otherFJSXXEAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/178524
description abstractThis test method covers the determination of the electrical conductance of concrete to provide a rapid indication of its resistance to the penetration of chloride ions. This test method is applicable to types of concrete where correlations have been established between this test procedure and long-term chloride ponding procedures such as those described in T 259. Examples of such correlations are discussed in References (1–5).1
The values stated in SI units are to be regarded as the standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
languageEnglish
titleAASHTO T 277num
titleStandard Method of Test for Electrical Indication of Concrete’s Ability to Resist Chloride Ion Penetrationen
typestandard
page12
statusActive
treeAASHTO - American Association of State Highway and Transportation Officials:;2011
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian