AASHTO T 273

Standard Method of Test for Soil Suction

Organization:
AASHTO - American Association of State Highway and Transportation Officials
Year: 2013

Abstract: This method covers the procedure for determining total soil suction force using thermocouple psychrometers. The test results of this method are to be used in conjunction with T 258. 
The thermocouple psychrometer measures the relative humidity in the soil by a technique called Peltier cooling. By causing a small direct current of approximately four to eight milliamperes to flow through the thermocouple junction for approximately 15 s in the correct direction, this junction will cool and water will condense on it when the dewpoint temperature is reached. Condensation of this water inhibits further cooling of the junction and the voltage difference developed between the thermocouple and the reference junctions can be measured using a microvoltmeter. With proper calibration, the thermocouple psychrometer output in microvolts can be converted directly to soil suction in convenient units of pressure. Typical thermocouple psychrometer output voltages vary from less than one microvolt for relative humidities close to 100 percent or total soil suction less than 95.76 kPa (1 tsf) to about 25 microvolts for relative humidities of about 95 percent or total soil suctions of about 5746 kPa (60 tsf). 
The following applies to all specified limits in this standard: For the purposes of determining conformance with these specifications, an observed value or a calculated value shall be rounded off "to the nearest unit" in the last right-hand place of figures used in expressing the limiting value, in accordance with ASTM E 29. 
The values stated in SI units are to be regarded as the standard.
URI: https://yse.yabesh.ir/std/handle/yse/185845
Collections :
  • AASHTO - American Association of State Highway and Transportation Officials
  • Download PDF : (1.817Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    AASHTO T 273

Show full item record

contributor authorAASHTO - American Association of State Highway and Transportation Officials
date accessioned2017-09-04T18:02:56Z
date available2017-09-04T18:02:56Z
date copyright1986.01.01 (R 2013)
date issued2013
identifier otherGCXVJFAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/185845
description abstractThis method covers the procedure for determining total soil suction force using thermocouple psychrometers. The test results of this method are to be used in conjunction with T 258. 
The thermocouple psychrometer measures the relative humidity in the soil by a technique called Peltier cooling. By causing a small direct current of approximately four to eight milliamperes to flow through the thermocouple junction for approximately 15 s in the correct direction, this junction will cool and water will condense on it when the dewpoint temperature is reached. Condensation of this water inhibits further cooling of the junction and the voltage difference developed between the thermocouple and the reference junctions can be measured using a microvoltmeter. With proper calibration, the thermocouple psychrometer output in microvolts can be converted directly to soil suction in convenient units of pressure. Typical thermocouple psychrometer output voltages vary from less than one microvolt for relative humidities close to 100 percent or total soil suction less than 95.76 kPa (1 tsf) to about 25 microvolts for relative humidities of about 95 percent or total soil suctions of about 5746 kPa (60 tsf). 
The following applies to all specified limits in this standard: For the purposes of determining conformance with these specifications, an observed value or a calculated value shall be rounded off "to the nearest unit" in the last right-hand place of figures used in expressing the limiting value, in accordance with ASTM E 29. 
The values stated in SI units are to be regarded as the standard.
languageEnglish
titleAASHTO T 273num
titleStandard Method of Test for Soil Suctionen
typestandard
page11
statusActive
treeAASHTO - American Association of State Highway and Transportation Officials:;2013
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian