English -- Safety requirements for electrical equipment for measurement, control and laboratory use – Part 2-010: Particular requirements for laboratory equipment for the heating of materials - Edition 4.0

IEC 61010-2-010 (REDLINE + STANDARD)

Organization:
IEC - International Electrotechnical Commission
Year: 2019

Abstract: Scope: Scope and object This clause of Part 1 is applicable except as follows: Equipment included in scope Replacement: Replace the second paragraph by the following: This part of IEC 61010 specifies particular safety requirements for whenever the following types a) to c) of electrical equipment and their accessories, wherever they are intended to be used, the heating of materials is one of the functions of the equipment. Addition: Add the following text after item c): It is possible that all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as within the scope of this standard. In that case, the requirements of those other Part 2 standards will also apply. In particular, if equipment is intended to be used for in vitro diagnostic (IVD) purposes, the requirements of IEC 610102101 will also apply. However, when the equipment incorporates a refrigerating system and a heating function where the combination of the two introduces additional or more severe HAZARDS than if treated separately, then it is possible that IEC 61010-2-012 is applicable instead of this Part 2-010. See further information in the flow chart (Figure 102) for the selection process and the guidance in the Introduction. Equipment excluded from scope Addition: Add the following items after item j): aa) equipment for the heating and ventilation of laboratories; bb) sterilizing equipment; cc) heating and/or cooling equipment which the OPERATOR is intended to enter, and which is large enough for the OPERATOR to remain inside with the door or doors closed.    
URI: https://yse.yabesh.ir/std/handle/yse/289102
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (809.9Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    English -- Safety requirements for electrical equipment for measurement, control and laboratory use – Part 2-010: Particular requirements for laboratory equipment for the heating of materials - Edition 4.0

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2020-09-15T22:28:45Z
date available2020-09-15T22:28:45Z
date copyright2019.02.01
date issued2019
identifier otherZAHZGGAAAAAAAAAA.pdf
identifier otherZAHZGGAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/289102
description abstractScope: Scope and object This clause of Part 1 is applicable except as follows: Equipment included in scope Replacement: Replace the second paragraph by the following: This part of IEC 61010 specifies particular safety requirements for whenever the following types a) to c) of electrical equipment and their accessories, wherever they are intended to be used, the heating of materials is one of the functions of the equipment. Addition: Add the following text after item c): It is possible that all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as within the scope of this standard. In that case, the requirements of those other Part 2 standards will also apply. In particular, if equipment is intended to be used for in vitro diagnostic (IVD) purposes, the requirements of IEC 610102101 will also apply. However, when the equipment incorporates a refrigerating system and a heating function where the combination of the two introduces additional or more severe HAZARDS than if treated separately, then it is possible that IEC 61010-2-012 is applicable instead of this Part 2-010. See further information in the flow chart (Figure 102) for the selection process and the guidance in the Introduction. Equipment excluded from scope Addition: Add the following items after item j): aa) equipment for the heating and ventilation of laboratories; bb) sterilizing equipment; cc) heating and/or cooling equipment which the OPERATOR is intended to enter, and which is large enough for the OPERATOR to remain inside with the door or doors closed.    
languageEnglish
titleEnglish -- Safety requirements for electrical equipment for measurement, control and laboratory use – Part 2-010: Particular requirements for laboratory equipment for the heating of materials - Edition 4.0en
titleIEC 61010-2-010 (REDLINE + STANDARD)num
typestandard
page80
statusActive
treeIEC - International Electrotechnical Commission:;2019
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian