French -- Expression des qualités de fonctionnement des analyseurs électrochimiques – Partie 4: Oxygène dissous dans l'eau mesuré par des capteurs ampérométriques recouverts d'une membrane - Edition 2.0|English -- Expression of performance of electrochemical analyzers – Part 4: Dissolved oxygen in water measured by membrane-covered amperometric sensors - Edition 2.0

IEC 60746-4

Organization:
IEC - International Electrotechnical Commission
Year: 2018

Abstract: Scope: This part of IEC 60746 is intended: • to specify terminology, definitions and requirements for statements by manufacturers for analyzers, sensor units and electronic units used for the determination of dissolved oxygen partial pressure or concentration; • to establish performance tests for such analyzers, sensor units and electronic units; • to provide basic documents to support the applications of quality assurance standards [1]1. This document applies to analyzers using membrane covered amperometric sensors. It applies to analyzers suitable for use in water containing liquids, ultrapure waters, fresh or potable water, sea water or other aqueous solutions, industrial or municipal waste water from water bodies (e.g. lakes, rivers, estuaries), as well as for industrial process streams and process liquids. Whilst in principle amperometric oxygen-analyzers are applicable in gaseous phases, the expression of performance in the gas phase is outside the scope of this document. This document is applicable to analyzers specified for permanent installation in any location (indoors or outdoors) using membrane-covered amperometric sensors 1 Numbers in square brackets refer to the Bibliography    
URI: https://yse.yabesh.ir/std/handle/yse/289151
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (5.018Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    French -- Expression des qualités de fonctionnement des analyseurs électrochimiques – Partie 4: Oxygène dissous dans l'eau mesuré par des capteurs ampérométriques recouverts d'une membrane - Edition 2.0|English -- Expression of performance of electrochemical analyzers – Part 4: Dissolved oxygen in water measured by membrane-covered amperometric sensors - Edition 2.0

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2020-09-15T22:28:58Z
date available2020-09-15T22:28:58Z
date copyright2018.12.01
date issued2018
identifier otherEIDQGGAAAAAAAAAA.pdf
identifier otherEIDQGGAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/289151
description abstractScope: This part of IEC 60746 is intended: • to specify terminology, definitions and requirements for statements by manufacturers for analyzers, sensor units and electronic units used for the determination of dissolved oxygen partial pressure or concentration; • to establish performance tests for such analyzers, sensor units and electronic units; • to provide basic documents to support the applications of quality assurance standards [1]1. This document applies to analyzers using membrane covered amperometric sensors. It applies to analyzers suitable for use in water containing liquids, ultrapure waters, fresh or potable water, sea water or other aqueous solutions, industrial or municipal waste water from water bodies (e.g. lakes, rivers, estuaries), as well as for industrial process streams and process liquids. Whilst in principle amperometric oxygen-analyzers are applicable in gaseous phases, the expression of performance in the gas phase is outside the scope of this document. This document is applicable to analyzers specified for permanent installation in any location (indoors or outdoors) using membrane-covered amperometric sensors 1 Numbers in square brackets refer to the Bibliography    
languageEnglish, French
titleFrench -- Expression des qualités de fonctionnement des analyseurs électrochimiques – Partie 4: Oxygène dissous dans l'eau mesuré par des capteurs ampérométriques recouverts d'une membrane - Edition 2.0|English -- Expression of performance of electrochemical analyzers – Part 4: Dissolved oxygen in water measured by membrane-covered amperometric sensors - Edition 2.0en
titleIEC 60746-4num
typestandard
page58
statusActive
treeIEC - International Electrotechnical Commission:;2018
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian