English -- Switches for appliances – Part 2-4: Particular requirements for independently mounted switches - Edition 2.0

IEC 61058-2-4 (REDLINE + STANDARD)

Organization:
IEC - International Electrotechnical Commission
Year: 2018

Abstract: Scope: Clause 1 of IEC 61058-1:2016 is applicable, except as follows. Addition: This document applies to independently mounted switches for appliances (mechanical or electronic) actuated by hand, by foot or by other human activity, to operate or control electrical appliances and other equipment for household or similar purposes with a rated voltage not exceeding 480 V and a rated current not exceeding 63 A. These switches are intended to be operated by a person, via an actuating member or by actuating a sensing unit. The actuating member or sensing unit can be integral with or arranged separately, either physically or electrically, from the switch and involve transmission of a signal, for example, electrical, optical, acoustic or thermal, between the actuating member or sensing unit and the switch. Switches which incorporate additional control functions governed by the switch function are within the scope of this document. This document also covers the indirect actuation of the switch when the operation of the actuating member or sensing unit is provided by a remote control or by a part of an appliance or equipment, such as a door. NOTE 1 Electronic switches can be combined with mechanical switches giving full disconnection or micro-disconnection. NOTE 2 Electronic switches without a mechanical switch in the supply circuit provide only electronic disconnection. Therefore, the circuit on the load side is always considered to be live. NOTE 3 For switches used in tropical climates, additional requirements can apply. NOTE 4 Attention is drawn to the fact that the standards for appliances can contain additional or alternative requirements for switches. NOTE 5 Throughout this document, the word "appliance" means "appliance or equipment".
URI: https://yse.yabesh.ir/std/handle/yse/289181
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (1.346Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    English -- Switches for appliances – Part 2-4: Particular requirements for independently mounted switches - Edition 2.0

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2020-09-15T22:29:05Z
date available2020-09-15T22:29:05Z
date copyright2018.10.01
date issued2018
identifier otherAKRJGGAAAAAAAAAA.pdf
identifier otherAKRJGGAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/289181
description abstractScope: Clause 1 of IEC 61058-1:2016 is applicable, except as follows. Addition: This document applies to independently mounted switches for appliances (mechanical or electronic) actuated by hand, by foot or by other human activity, to operate or control electrical appliances and other equipment for household or similar purposes with a rated voltage not exceeding 480 V and a rated current not exceeding 63 A. These switches are intended to be operated by a person, via an actuating member or by actuating a sensing unit. The actuating member or sensing unit can be integral with or arranged separately, either physically or electrically, from the switch and involve transmission of a signal, for example, electrical, optical, acoustic or thermal, between the actuating member or sensing unit and the switch. Switches which incorporate additional control functions governed by the switch function are within the scope of this document. This document also covers the indirect actuation of the switch when the operation of the actuating member or sensing unit is provided by a remote control or by a part of an appliance or equipment, such as a door. NOTE 1 Electronic switches can be combined with mechanical switches giving full disconnection or micro-disconnection. NOTE 2 Electronic switches without a mechanical switch in the supply circuit provide only electronic disconnection. Therefore, the circuit on the load side is always considered to be live. NOTE 3 For switches used in tropical climates, additional requirements can apply. NOTE 4 Attention is drawn to the fact that the standards for appliances can contain additional or alternative requirements for switches. NOTE 5 Throughout this document, the word "appliance" means "appliance or equipment".
languageEnglish
titleEnglish -- Switches for appliances – Part 2-4: Particular requirements for independently mounted switches - Edition 2.0en
titleIEC 61058-2-4 (REDLINE + STANDARD)num
typestandard
page72
statusActive
treeIEC - International Electrotechnical Commission:;2018
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian