French -- Appareillage à haute tension – Partie 214: Classification arc interne des appareillages sous enveloppe métallique de tensions assignées supérieures à 1 kV et inférieures ou égales à 52 kV montés sur poteau - Edition 1.0|English -- High-voltage switchgear and controlgear – Part 214: Internal arc classification for metal-enclosed pole-mounted switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV - Edition 1.0

IEC 62271-214

Organization:
IEC - International Electrotechnical Commission
Year: 2019

Abstract: Scope: This part of IEC 62271 specifies requirements for internal arc classification of metal-enclosed pole-mounted switchgear installations used for alternating current with rated voltages above 1 kV and up to and including 52 kV with service frequencies up to and including 60 Hz. This document is applicable to three-phase, two-phase and single phase equipment. Enclosures may include fixed and removable components and may be filled with fluid (liquid or gas) to provide insulation. NOTE For the use of this document high-voltage (IEC 60050-601:1985, 601-01-27) is the rated voltage above 1 000 V. However, medium voltage (IEC 60050-601:1985, 601-01-28) is commonly used for distribution systems with voltages above 1 kV and generally applied up to and including 52 kV; refer to [1] of the Bibliography. This document does not preclude that other equipment may be included in the same enclosure. In such a case, any possible influence of that equipment on the switchgear and controlgear is to be taken into account.
URI: https://yse.yabesh.ir/std/handle/yse/289185
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (2.081Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    French -- Appareillage à haute tension – Partie 214: Classification arc interne des appareillages sous enveloppe métallique de tensions assignées supérieures à 1 kV et inférieures ou égales à 52 kV montés sur poteau - Edition 1.0|English -- High-voltage switchgear and controlgear – Part 214: Internal arc classification for metal-enclosed pole-mounted switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV - Edition 1.0

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2020-09-15T22:29:06Z
date available2020-09-15T22:29:06Z
date copyright2019.06.01
date issued2019
identifier otherGSXDIGAAAAAAAAAA.pdf
identifier otherGSXDIGAAAAAAAAAA.pdf
identifier urihttps://yse.yabesh.ir/std/handle/yse/289185
description abstractScope: This part of IEC 62271 specifies requirements for internal arc classification of metal-enclosed pole-mounted switchgear installations used for alternating current with rated voltages above 1 kV and up to and including 52 kV with service frequencies up to and including 60 Hz. This document is applicable to three-phase, two-phase and single phase equipment. Enclosures may include fixed and removable components and may be filled with fluid (liquid or gas) to provide insulation. NOTE For the use of this document high-voltage (IEC 60050-601:1985, 601-01-27) is the rated voltage above 1 000 V. However, medium voltage (IEC 60050-601:1985, 601-01-28) is commonly used for distribution systems with voltages above 1 kV and generally applied up to and including 52 kV; refer to [1] of the Bibliography. This document does not preclude that other equipment may be included in the same enclosure. In such a case, any possible influence of that equipment on the switchgear and controlgear is to be taken into account.
languageEnglish, French
titleFrench -- Appareillage à haute tension – Partie 214: Classification arc interne des appareillages sous enveloppe métallique de tensions assignées supérieures à 1 kV et inférieures ou égales à 52 kV montés sur poteau - Edition 1.0|English -- High-voltage switchgear and controlgear – Part 214: Internal arc classification for metal-enclosed pole-mounted switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV - Edition 1.0en
titleIEC 62271-214num
typestandard
page66
statusActive
treeIEC - International Electrotechnical Commission:;2019
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian