KSC-MMA-1985-79 REV 6
STANDARD TEST METHOD FOR EVALUATING TRIBOELECTRIC CHARGE GENERATION AND DECAY
Organization:
KSC - NASA - KSC - Kennedy Space Center
Year: 2008
Abstract: This method describes the triboelectric test device used at the Kennedy Space Center (KSC) for electrostatic evaluation of non-conducting materials, including sample preparation and preconditioning, test procedure, and calibration requirements. This method is intended for testing thin plastic films, foams, tapes, cloth fabrics, solid surfaces up to 0.5 inch thick, and surface coatings such as paint or anti-static coatings applied to thin solid samples.
Collections
:
-
Statistics
KSC-MMA-1985-79 REV 6
Show full item record
contributor author | KSC - NASA - KSC - Kennedy Space Center | |
date accessioned | 2017-09-04T15:37:14Z | |
date available | 2017-09-04T15:37:14Z | |
date copyright | 07/24/2008 | |
date issued | 2008 | |
identifier other | OUJRLCAAAAAAAAAA.pdf | |
identifier uri | https://yse.yabesh.ir/std/handle/yse/39131 | |
description abstract | This method describes the triboelectric test device used at the Kennedy Space Center (KSC) for electrostatic evaluation of non-conducting materials, including sample preparation and preconditioning, test procedure, and calibration requirements. This method is intended for testing thin plastic films, foams, tapes, cloth fabrics, solid surfaces up to 0.5 inch thick, and surface coatings such as paint or anti-static coatings applied to thin solid samples. | |
title | KSC-MMA-1985-79 REV 6 | num |
title | STANDARD TEST METHOD FOR EVALUATING TRIBOELECTRIC CHARGE GENERATION AND DECAY | en |
type | standard | |
page | 8 | |
status | Active | |
tree | KSC - NASA - KSC - Kennedy Space Center:;2008 | |
contenttype | fulltext |